flexible riser
CFIHOS
TagAndEquipmentClass
ID: CFIHOS-30000828
Faça login para ver esta definição.
Hierarchy
Broader / Parent
- riser CFIHOS
Properties / Attributes (19)
| Name | Data Type | Unit / Valid values | Required | Definition |
|---|---|---|---|---|
| design specification | Text |
— | Optional | A specification according to which an item is intended to be designed |
| external corrosion protection | Text |
— | Optional | Specify the external corrosion protection type |
| fluid name | Text |
— | Optional | The name of the product in liquid or gas phase. |
| lower limit operating pressure | Number |
PRESS | Optional | A pressure which is the lowest pressure at which a functional or physical object is expected to operate. |
| lower limit operating temperature | Number |
degree celsius | Optional | A temperature that is the lowest temperature at which a functional or physical object is expected to operate. |
| normal operating pressure | Number |
bar gauge | Optional | A pressure at which a functional or physical object is expected to operate normally. |
| normal operating temperature | Number |
degree celsius | Optional | A temperature at which a functional or physical object is expected to operate normally. |
| upper limit operating pressure | Number |
bar gauge | Optional | A pressure which is the highest pressure at which a functional or physical object is expected to operate. |
| upper limit operating temperature | Number |
degree celsius | Optional | A temperature that is the highest temperature at which a functional or physical object is expected to operate. |
| asphaltenes | Boolean |
— | Optional | Specify if asphaltenes is present or not. |
| corrosion inhibitor | Boolean |
— | Optional | Specify if corrosion inhibitor present or not. |
| fluid corrosiveness | Text |
— | Optional | Specify which type of corrosive agents are present in the process fluid. |
| gas lift | Boolean |
— | Optional | Specify if gas lift is installed or not. |
| hydrate formation | Boolean |
— | Optional | Specify if hydration formation occurred or not. |
| mechanical protection | Text |
— | Optional | Specify the type of mechanical protection. |
| riser layout | Text |
— | Optional | Specify the type of layout for riser. |
| sand production | Boolean |
— | Optional | Specify if sand produced or not. |
| scale formation | Boolean |
— | Optional | Specify if scale formation occurred or not. |
| wax formation | Boolean |
— | Optional | Specify if wax formation occurred or not. |