Core Ontology for Petroleum Installations · INF-UFRGS-Ontologies · CNPq INF-UFRGS-ENERGIA inf.ufrgs.br/ontologies/copi dee69df

turbine

CFIHOS TagAndEquipmentClass

ID: CFIHOS-30000685

Faça login para ver esta definição.

Hierarchy

Broader / Parent

Narrower / Children

Properties / Attributes (43)
Name Data Type Unit / Valid values Required Definition
design specification Text — Optional A specification according to which an item is intended to be designed
direction of rotation Text — Optional Specify the direction of rotation of the functional or physical object.
driven unit normal operating shaft power Number kilowatt Optional The shaft power under rated conditions for the equipment which is driven by the functional or physical object.
driven unit normal speed Number revolution per minute Optional The rotational speed which is the normal operating speed for the equipment which is driven by the functional or physical object.
explosion protection gas group Text — Optional Specify the gas group classification of the physical object in accordance with IEC/EN 60079-20
explosion protection temperature class Text — Optional Specify the temperature classification of the physical object in accordance with CENELEC EN50014
explosion protection zone Text — Optional Specify the hazardous zone in which the functional or physical object is expected to operate.
explosion rated item Boolean — Optional An indicator that an equipment has been classified as safe for use in hazardous areas
fuel type Text — Optional The type of fuel required by an equipment item. For example 'fuel gas, diesel etc.
lower limit operating inlet pressure Number PRESS Optional The pressure which is the lowest pressure at which a functional or physical object is expected to operate at its inlet connection.
lower limit operating inlet temperature Number TEMP Optional The temperature which is the lowest temperature at which a functional or physical object is expected to operate at its inlet connection.
lower limit operating outlet pressure Number PRESS Optional The pressure which is the lowest pressure at which a functional or physical object is expected to operate at its outlet connection.
lower limit operating outlet temperature Number TEMP Optional The temperature which is the lowest temperature at which a functional or physical object is expected to operate at its outlet connection.
lower limit operating temperature Number degree celsius Optional A temperature that is the lowest temperature at which a functional or physical object is expected to operate.
lower limit output power Number kilowatt Optional The power which is the minimum power a functional or physical object is expected to deliver.
normal operating cooling water inlet temperature Number degree celsius Optional The temperature at which a functional or physical objects cooling water is expected to operate at its inlet connection.
normal operating extraction steam mass flow rate Number kilogram per hour Optional The mass flow rate which is the extraction steam mass flow rate at which a functional or physical object is expected to operate normally.
normal operating extraction steam pressure Number kilopascal gauge Optional The pressure which is the extraction steam pressure at which a functional or physical object is expected to operate normally.
normal operating extraction steam temperature Number degree celsius Optional The temperature which is the extraction steam temperature at which a functional or physical object is expected to operate normally.
normal operating inlet pressure Number bar absolute Optional An inlet pressure at which a functional or physical object is expected to operate normally.
normal operating inlet steam pressure Number kilopascal gauge Optional The pressure at which a functional or physical object is expected to operate normally at its inlet steam.
normal operating inlet steam temperature Number TEMP Optional The temperature at which a functional or physical object is expected to operate normally at its inlet steam.
normal operating inlet temperature Number degree celsius Optional The temperature at which a functional or physical object is expected to operate normally at its inlet connection.
normal operating outlet pressure Number bar absolute Optional The pressure at which a functional or physical object is expected to operate normally at its outlet connection.
normal operating outlet steam pressure Number kilopascal gauge Optional The pressure at which a functional or physical object is expected to operate normally at its outlet steam.
normal operating outlet steam temperature Number degree celsius Optional The temperature at which a functional or physical object is expected to operate normally at its outlet steam.
normal operating outlet temperature Number degree celsius Optional Is a temperature that occurs during operation or under which an object is supposed to operate.
normal operating rotational speed Number revolution per minute Optional The rotational speed which is the normal operating rotational speed for the functional or physical object.
normal output power Number kilowatt Optional The power which is the power a functional or physical object deliver normally.
number of shafts Number piece Optional Specifies the number of shafts for this functional or physical object.
operation continuous intermittent Text — Optional Specifies if the equipment is working continuously or in an intermittent way.
test medium Text — Optional The medium used for testing purpose.
test pressure Number bar gauge Optional A pressure to which an object should be subjected to test for leakage and structural integrity.
thermal insulation class Text — Optional The class of electrical insulation used by a physical object.
turbine cycle Text — Optional Specify if the working medium passes successively through the compressor, the combustor and the turbine in a simple cycle, or if the turbine exhaust is used to preheat the combustion air from the compressor in a regenerative cycle.
upper limit cooling water outlet temperature Number degree celsius Optional The temperature which is the highest cooling water temperature at which a functional or physical object is expected to operate at its outlet connection.
upper limit operating inlet pressure Number bar absolute Optional The pressure which is the highest pressure at which a functional or physical object is expected to operate at its inlet connection.
upper limit operating inlet temperature Number TEMP Optional The temperature which is the highest temperature at which a functional or physical object is expected to operate at its inlet connection.
upper limit operating outlet pressure Number PRESS Optional The pressure which is the highest pressure at which a functional or physical object is expected to operate at its outlet connection.
upper limit operating outlet temperature Number TEMP Optional The temperature which is the highest temperature at which a functional or physical object is expected to operate at its outlet connection.
upper limit operating pressure Number bar gauge Optional A pressure which is the highest pressure at which a functional or physical object is expected to operate.
upper limit operating temperature Number degree celsius Optional A temperature that is the highest temperature at which a functional or physical object is expected to operate.
driven equipment Text — Optional Specify the equipment being driven

Suggest a change

Opens a pre-filled GitHub issue on the COPI repo — nothing is sent until you submit it there.