gas turbine
CFIHOS
TagAndEquipmentClass
ID: CFIHOS-30000534
Faça login para ver esta definição.
Hierarchy
Broader / Parent
- turbine CFIHOS
Properties / Attributes (61)
| Name | Data Type | Unit / Valid values | Required | Definition |
|---|---|---|---|---|
| ATEX category | Text |
— | Optional | Specify in which category the physical object is divided in accordance with the directive 94/9/EC. |
| design specification | Text |
— | Optional | A specification according to which an item is intended to be designed |
| direction of rotation | Text |
— | Optional | Specify the direction of rotation of the functional or physical object. |
| driven unit normal operating shaft power | Number |
kilowatt | Optional | The shaft power under rated conditions for the equipment which is driven by the functional or physical object. |
| driven unit normal speed | Number |
revolution per minute | Optional | The rotational speed which is the normal operating speed for the equipment which is driven by the functional or physical object. |
| explosion protection gas group | Text |
— | Optional | Specify the gas group classification of the physical object in accordance with IEC/EN 60079-20 |
| explosion protection temperature class | Text |
— | Optional | Specify the temperature classification of the physical object in accordance with CENELEC EN50014 |
| explosion protection zone | Text |
— | Optional | Specify the hazardous zone in which the functional or physical object is expected to operate. |
| explosion rated item | Boolean |
— | Optional | An indicator that an equipment has been classified as safe for use in hazardous areas |
| fuel type | Text |
— | Optional | The type of fuel required by an equipment item. For example 'fuel gas, diesel etc. |
| lower limit operating inlet pressure | Number |
PRESS | Optional | The pressure which is the lowest pressure at which a functional or physical object is expected to operate at its inlet connection. |
| lower limit operating inlet temperature | Number |
TEMP | Optional | The temperature which is the lowest temperature at which a functional or physical object is expected to operate at its inlet connection. |
| lower limit operating outlet pressure | Number |
PRESS | Optional | The pressure which is the lowest pressure at which a functional or physical object is expected to operate at its outlet connection. |
| lower limit operating outlet temperature | Number |
TEMP | Optional | The temperature which is the lowest temperature at which a functional or physical object is expected to operate at its outlet connection. |
| lower limit operating temperature | Number |
degree celsius | Optional | A temperature that is the lowest temperature at which a functional or physical object is expected to operate. |
| lower limit output power | Number |
kilowatt | Optional | The power which is the minimum power a functional or physical object is expected to deliver. |
| normal operating cooling water inlet temperature | Number |
degree celsius | Optional | The temperature at which a functional or physical objects cooling water is expected to operate at its inlet connection. |
| normal operating extraction steam mass flow rate | Number |
kilogram per hour | Optional | The mass flow rate which is the extraction steam mass flow rate at which a functional or physical object is expected to operate normally. |
| normal operating extraction steam pressure | Number |
kilopascal gauge | Optional | The pressure which is the extraction steam pressure at which a functional or physical object is expected to operate normally. |
| normal operating extraction steam temperature | Number |
degree celsius | Optional | The temperature which is the extraction steam temperature at which a functional or physical object is expected to operate normally. |
| normal operating inlet pressure | Number |
bar absolute | Optional | An inlet pressure at which a functional or physical object is expected to operate normally. |
| normal operating inlet steam pressure | Number |
kilopascal gauge | Optional | The pressure at which a functional or physical object is expected to operate normally at its inlet steam. |
| normal operating inlet steam temperature | Number |
TEMP | Optional | The temperature at which a functional or physical object is expected to operate normally at its inlet steam. |
| normal operating inlet temperature | Number |
degree celsius | Optional | The temperature at which a functional or physical object is expected to operate normally at its inlet connection. |
| normal operating outlet pressure | Number |
bar absolute | Optional | The pressure at which a functional or physical object is expected to operate normally at its outlet connection. |
| normal operating outlet steam pressure | Number |
kilopascal gauge | Optional | The pressure at which a functional or physical object is expected to operate normally at its outlet steam. |
| normal operating outlet steam temperature | Number |
degree celsius | Optional | The temperature at which a functional or physical object is expected to operate normally at its outlet steam. |
| normal operating outlet temperature | Number |
degree celsius | Optional | Is a temperature that occurs during operation or under which an object is supposed to operate. |
| normal operating rotational speed | Number |
revolution per minute | Optional | The rotational speed which is the normal operating rotational speed for the functional or physical object. |
| normal output power | Number |
kilowatt | Optional | The power which is the power a functional or physical object deliver normally. |
| number of shafts | Number |
piece | Optional | Specifies the number of shafts for this functional or physical object. |
| operation continuous intermittent | Text |
— | Optional | Specifies if the equipment is working continuously or in an intermittent way. |
| safety integrity level | Text |
— | Optional | A relative level of risk-reduction provided by a safety function, or to specify a target level of risk reduction |
| test medium | Text |
— | Optional | The medium used for testing purpose. |
| test pressure | Number |
bar gauge | Optional | A pressure to which an object should be subjected to test for leakage and structural integrity. |
| thermal insulation class | Text |
— | Optional | The class of electrical insulation used by a physical object. |
| turbine cycle | Text |
— | Optional | Specify if the working medium passes successively through the compressor, the combustor and the turbine in a simple cycle, or if the turbine exhaust is used to preheat the combustion air from the compressor in a regenerative cycle. |
| upper limit cooling water outlet temperature | Number |
degree celsius | Optional | The temperature which is the highest cooling water temperature at which a functional or physical object is expected to operate at its outlet connection. |
| upper limit design pressure | Number |
PRESS | Optional | The highest pressure at which a functional or physical object is designed for. |
| upper limit design temperature | Number |
TEMP | Optional | The highest temperature at which a functional or physical object is designed. |
| upper limit operating inlet pressure | Number |
bar absolute | Optional | The pressure which is the highest pressure at which a functional or physical object is expected to operate at its inlet connection. |
| upper limit operating inlet temperature | Number |
TEMP | Optional | The temperature which is the highest temperature at which a functional or physical object is expected to operate at its inlet connection. |
| upper limit operating outlet pressure | Number |
PRESS | Optional | The pressure which is the highest pressure at which a functional or physical object is expected to operate at its outlet connection. |
| upper limit operating outlet temperature | Number |
TEMP | Optional | The temperature which is the highest temperature at which a functional or physical object is expected to operate at its outlet connection. |
| upper limit operating pressure | Number |
bar gauge | Optional | A pressure which is the highest pressure at which a functional or physical object is expected to operate. |
| upper limit operating temperature | Number |
degree celsius | Optional | A temperature that is the highest temperature at which a functional or physical object is expected to operate. |
| ATEX explosive atmosphere | Text |
— | Optional | Specify in which explosive atmosphere the physical object is divided in accordance with the directive 94/9/EC. |
| ATEX group | Text |
— | Optional | Specify in which group the physical object is divided in accordance with the directive 94/9/EC. |
| bearing lubrication | Text |
— | Optional | The method of lubrication of the bearings. |
| driven equipment | Text |
— | Optional | Specify the equipment being driven |
| dry weight | Number |
kilogram | Optional | A weight of an object excluding any operating or process fluids. |
| explosion protection concept | Text |
— | Optional | Specify the identification of electrical equipment's explosion protection and type of ignition protection in accordance with IEC/EN 60079-0. |
| explosion protection examination certificate number | Text |
— | Optional | The examination certificate number for the physical object issued by a notified body. |
| explosion protection material group | Text |
— | Optional | Specify for purposes of testing, approval, and area classification, various air mixtures (not oxygen-enriched) grouped in accordance with 500.6(A) and (B). |
| explosion protection notified body | Text |
— | Optional | The name of the nationally accredited approval body that has issued the examination certificate for the physical object. |
| ingress protection | Text |
— | Optional | Specify the degree of ingress protection for the physical object in accordance with IEC/EN 50629 or NEMA, UL and CSA type rating. |
| rated fuel consumption | Number |
MASFLO | Optional | Fuel mass flow rate at rated conditions |
| rated output power | Number |
kilowatt | Optional | A power that is the power a motor has been designed to deliver under specified conditions. |
| rated speed | Number |
revolution per minute | Optional | The rotational speed a functional or physical object is designed to deliver under specified conditions. |
| trip speed | Number |
ANGVEL | Optional | The speed of which the machine will trip |
| upper limit allowable speed | Number |
revolution per minute | Optional | The speed which is the highest allowed. |