pump
CFIHOS
TagAndEquipmentClass
ID: CFIHOS-30000550
Faça login para ver esta definição.
Hierarchy
Properties / Attributes (36)
| Name | Data Type | Unit / Valid values | Required | Definition |
|---|---|---|---|---|
| density | Number |
DENSI | Optional | The mass per unit volume of an object or a fluid |
| design specification | Text |
— | Optional | A specification according to which an item is intended to be designed |
| explosion protection gas group | Text |
— | Optional | Specify the gas group classification of the physical object in accordance with IEC/EN 60079-20 |
| explosion protection temperature class | Text |
— | Optional | Specify the temperature classification of the physical object in accordance with CENELEC EN50014 |
| explosion protection zone | Text |
— | Optional | Specify the hazardous zone in which the functional or physical object is expected to operate. |
| explosion rated item | Boolean |
— | Optional | An indicator that an equipment has been classified as safe for use in hazardous areas |
| fluid name | Text |
— | Optional | The name of the product in liquid or gas phase. |
| immersed | Boolean |
— | Optional | Specify if the functional or physical object can be immersed or not. |
| lower limit ambient operating temperature | Number |
degree celsius | Optional | The temperature which is the lowest ambient temperature at which a functional or physical object is expected to operate. |
| lower limit design temperature | Number |
degree celsius | Optional | The lowest temperature at which a functional or physical object is designed. |
| lower limit operating inlet pressure | Number |
PRESS | Optional | The pressure which is the lowest pressure at which a functional or physical object is expected to operate at its inlet connection. |
| lower limit operating outlet pressure | Number |
PRESS | Optional | The pressure which is the lowest pressure at which a functional or physical object is expected to operate at its outlet connection. |
| lower limit operating temperature | Number |
degree celsius | Optional | A temperature that is the lowest temperature at which a functional or physical object is expected to operate. |
| lower limit operating volume flow rate | Number |
cubic metre per hour | Optional | A volume flow rate that is the lowest volume flow rate at which a functional or physical object is expected to operate. |
| net positive suction head available | Number |
metre | Optional | NPSH for a particular pumping system at a certain flow rate and temperature. |
| normal operating dynamic viscosity | Number |
millipascal second | Optional | The dynamic viscosity at which a functional or physical object is expected to operate normally. |
| normal operating inlet pressure | Number |
bar absolute | Optional | An inlet pressure at which a functional or physical object is expected to operate normally. |
| normal operating inlet temperature | Number |
degree celsius | Optional | The temperature at which a functional or physical object is expected to operate normally at its inlet connection. |
| normal operating liquid dynamic viscosity | Number |
VISDYN | Optional | The dynamic viscosity of the fluid in liquid phase at which a functional or physical object is expected to operate normally. |
| normal operating outlet pressure | Number |
bar absolute | Optional | The pressure at which a functional or physical object is expected to operate normally at its outlet connection. |
| normal operating temperature | Number |
degree celsius | Optional | A temperature at which a functional or physical object is expected to operate normally. |
| normal operating volume flow rate | Number |
VOLFLO | Optional | The volume flow rate at which a functional or physical object is expected to operate normally. |
| operation continuous intermittent | Text |
— | Optional | Specifies if the equipment is working continuously or in an intermittent way. |
| operation single/parallel | Text |
— | Optional | Specifies if the equipment is working alone or with similar equipment in parallel. |
| orientation | Text |
— | Optional | The mount position of an equipment such as horizontal, vertical or submerged |
| pump type | Text |
— | Optional | The pump type selected on a pump's specification sheet |
| test medium | Text |
— | Optional | The medium used for testing purpose. |
| test pressure | Number |
bar gauge | Optional | A pressure to which an object should be subjected to test for leakage and structural integrity. |
| thermal insulation class | Text |
— | Optional | The class of electrical insulation used by a physical object. |
| upper limit ambient operating temperature | Number |
degree celsius | Optional | The temperature which is the highest ambient temperature at which a functional or physical object is expected to operate. |
| upper limit design pressure | Number |
bar gauge | Optional | The highest pressure at which a functional or physical object is designed for. |
| upper limit design temperature | Number |
degree celsius | Optional | The highest temperature at which a functional or physical object is designed. |
| upper limit operating inlet pressure | Number |
bar absolute | Optional | The pressure which is the highest pressure at which a functional or physical object is expected to operate at its inlet connection. |
| upper limit operating outlet pressure | Number |
PRESS | Optional | The pressure which is the highest pressure at which a functional or physical object is expected to operate at its outlet connection. |
| upper limit operating temperature | Number |
degree celsius | Optional | A temperature that is the highest temperature at which a functional or physical object is expected to operate. |
| upper limit operating volume flow rate | Number |
VOLFLO | Optional | A volume flow rate that is the highest volume flow rate at which a functional or physical object is expected to operate. |