Core Ontology for Petroleum Installations · INF-UFRGS-Ontologies · CNPq INF-UFRGS-ENERGIA inf.ufrgs.br/ontologies/copi dee69df

pump

CFIHOS TagAndEquipmentClass

ID: CFIHOS-30000550

Faça login para ver esta definição.

Hierarchy
Properties / Attributes (36)
Name Data Type Unit / Valid values Required Definition
density Number DENSI Optional The mass per unit volume of an object or a fluid
design specification Text — Optional A specification according to which an item is intended to be designed
explosion protection gas group Text — Optional Specify the gas group classification of the physical object in accordance with IEC/EN 60079-20
explosion protection temperature class Text — Optional Specify the temperature classification of the physical object in accordance with CENELEC EN50014
explosion protection zone Text — Optional Specify the hazardous zone in which the functional or physical object is expected to operate.
explosion rated item Boolean — Optional An indicator that an equipment has been classified as safe for use in hazardous areas
fluid name Text — Optional The name of the product in liquid or gas phase.
immersed Boolean — Optional Specify if the functional or physical object can be immersed or not.
lower limit ambient operating temperature Number degree celsius Optional The temperature which is the lowest ambient temperature at which a functional or physical object is expected to operate.
lower limit design temperature Number degree celsius Optional The lowest temperature at which a functional or physical object is designed.
lower limit operating inlet pressure Number PRESS Optional The pressure which is the lowest pressure at which a functional or physical object is expected to operate at its inlet connection.
lower limit operating outlet pressure Number PRESS Optional The pressure which is the lowest pressure at which a functional or physical object is expected to operate at its outlet connection.
lower limit operating temperature Number degree celsius Optional A temperature that is the lowest temperature at which a functional or physical object is expected to operate.
lower limit operating volume flow rate Number cubic metre per hour Optional A volume flow rate that is the lowest volume flow rate at which a functional or physical object is expected to operate.
net positive suction head available Number metre Optional NPSH for a particular pumping system at a certain flow rate and temperature.
normal operating dynamic viscosity Number millipascal second Optional The dynamic viscosity at which a functional or physical object is expected to operate normally.
normal operating inlet pressure Number bar absolute Optional An inlet pressure at which a functional or physical object is expected to operate normally.
normal operating inlet temperature Number degree celsius Optional The temperature at which a functional or physical object is expected to operate normally at its inlet connection.
normal operating liquid dynamic viscosity Number VISDYN Optional The dynamic viscosity of the fluid in liquid phase at which a functional or physical object is expected to operate normally.
normal operating outlet pressure Number bar absolute Optional The pressure at which a functional or physical object is expected to operate normally at its outlet connection.
normal operating temperature Number degree celsius Optional A temperature at which a functional or physical object is expected to operate normally.
normal operating volume flow rate Number VOLFLO Optional The volume flow rate at which a functional or physical object is expected to operate normally.
operation continuous intermittent Text — Optional Specifies if the equipment is working continuously or in an intermittent way.
operation single/parallel Text — Optional Specifies if the equipment is working alone or with similar equipment in parallel.
orientation Text — Optional The mount position of an equipment such as horizontal, vertical or submerged
pump type Text — Optional The pump type selected on a pump's specification sheet
test medium Text — Optional The medium used for testing purpose.
test pressure Number bar gauge Optional A pressure to which an object should be subjected to test for leakage and structural integrity.
thermal insulation class Text — Optional The class of electrical insulation used by a physical object.
upper limit ambient operating temperature Number degree celsius Optional The temperature which is the highest ambient temperature at which a functional or physical object is expected to operate.
upper limit design pressure Number bar gauge Optional The highest pressure at which a functional or physical object is designed for.
upper limit design temperature Number degree celsius Optional The highest temperature at which a functional or physical object is designed.
upper limit operating inlet pressure Number bar absolute Optional The pressure which is the highest pressure at which a functional or physical object is expected to operate at its inlet connection.
upper limit operating outlet pressure Number PRESS Optional The pressure which is the highest pressure at which a functional or physical object is expected to operate at its outlet connection.
upper limit operating temperature Number degree celsius Optional A temperature that is the highest temperature at which a functional or physical object is expected to operate.
upper limit operating volume flow rate Number VOLFLO Optional A volume flow rate that is the highest volume flow rate at which a functional or physical object is expected to operate.

Suggest a change

Opens a pre-filled GitHub issue on the COPI repo — nothing is sent until you submit it there.