Core Ontology for Petroleum Installations · INF-UFRGS-Ontologies · CNPq INF-UFRGS-ENERGIA inf.ufrgs.br/ontologies/copi dee69df

centrifugal pump

CFIHOS TagAndEquipmentClass

ID: CFIHOS-30000521

Faça login para ver esta definição.

Hierarchy

Broader / Parent

Properties / Attributes (316)
Name Data Type Unit / Valid values Required Definition
accelerometers mounting location Text — Optional Specify the required mounting locations for the accelerometers.
accelerometers requirement Text — Optional Specify if accelerometers are required..
additional central flush port Text — Optional Specify if an additional, centrally located, flush port on the top of the mechanical seal gland plate is required..
additional components positive material identification tested Text — Optional Specify the additional components to be subjected to positive material identification (PMI) testing.
additional sub-surface ultrasonic or radiographic examination Text — Optional Specify the type of sub-surface examination required for the components to be subjected to additional surface/sub-surface examination.
additional surface magnetic particle or liquid penetrant examination Text — Optional Specify the type of surface examination required for components to be subjected to additional surface/sub-surface examination.
additional surface/sub-surface examination Text — Optional Specify if any additional surface/sub-surface examination is required.
additional surface/sub-surface examination components Text — Optional Specify the components to be subjected to additional surface/sub-surface examination.
alternate flow positive suction head available Number metre Optional NPSHA that is available for a particular pumping system at alternate flow condition.
alternate operating temperature Number degree celsius Optional The temperature at an alternate case at which a functional or physical object is expected to operate.
alternate operating volume flow rate Number cubic metre per hour Optional A volume flow rate that is the alternate conditions volume flow rate at which a functional or physical object is expected to operate.
alternative design differential pressure Number bar Optional The differential pressure at which a functional or physical object is designed for in alternate conditions.
alternative operating differential head pressure Number bar Optional The rated differential pressure head at which a functional or physical object is expected to operate in alternate conditions.
alternative operating pressure Number bar Optional The rated pressure at which a functional or physical object is expected to operate in alternate conditions.
API Standard 682 data sheet attached Text — Optional Specify if an API Standard 682 mechanical seal data sheet is required for the proposed pump.
API Standard 682 mechanical seal code Text — Optional Specify the API Standard 682 mechanical seal code required for the proposed pump.
applicable to Text — Optional Specify the procurement status of the data sheet.
auxiliary process-liquid lines, fittings and other connections to casing, including seal plans material Text — Optional Specify the auxiliary process-liquid lines, fittings and other connections to casing, including seal plans materials of construction required.
auxiliary process-liquid piping construction Text — Optional Specify the proposed pump auxiliary process-liquid piping construction required.
average ambient operating pressure at equipment location Number bar absolute Optional The average ambient pressure at the plant's location.
bearing housing cooling method Text — Optional Specify the pump bearing housing cooling method required.
bearing lubrication lines material Text — Optional The material from which the bearing lubrication lines is constructed.
bearing lubrication method Text — Optional Specify the lubrication method for the proposed pump bearings.
bearing lubrication specification Text — Optional Is a specification which describes the bearing lubricant.
bearing retainer or spider material Text — Optional The material from which the bearing retainer or spider is constructed.
bellmouth/suction cover material Text — Optional The material from which the bellmouth/suction cover is constructed.
bowl bearing material Text — Optional The material from which the bowl bearing is constructed.
bowl shaft material Text — Optional The material from which the bowl shaft is constructed.
bowl/casing material Text — Optional The material from which the bowl/casing is constructed.
case and case cover material Text — Optional The material from which the case and case cover is constructed.
case wear ring material Text — Optional The material from which the case wear ring is constructed.
chloride concentration Number part per million Optional Specifies the level of chloride in the liquid.
component balance to ISO 21940-11, Grade G1.0 Text — Optional Specify whether the proposed pump rotating components are required to be dynamically balanced to ISO 21940-11, Grade G1.0.
conformity assessment system level Text — Optional The Conformity Assessment System (CAS) class letter in accordance with IOGP specification and obligatory requirements.
cooling water piping plan Text — Optional Specify the pump cooling water plan required. Refer to Annex B for piping plans.
cooling water type Text — Optional The type or quality of the required cooling water.
corrosion due to Text — Optional Description of the cause of the expected corrosion.
country region Text — Optional Geographic location of the project within a country which will determine the applicability of local regulatory requirements.
density Number DENSI Optional The mass per unit volume of an object or a fluid
design approval prior to fabrication Text — Optional Specify if design approval prior to fabrication is required for the proposed equipment or part of equipment.
design specification Text — Optional A specification according to which an item is intended to be designed
diffuser material Text — Optional The material from which the diffuser is constructed.
discharge column material Text — Optional The material from which the discharge column is constructed.
discharge elbow and pipe material Text — Optional The material from which the discharge elbow and pipe is constructed.
discharge head material Text — Optional The material from which the discharge head is constructed.
discharge nozzle position Text — Optional Specify the discharge nozzle flange position.
drain valve supplied by Text — Optional Specify who is responsible for supplying the drain valve.
driver type Text — Optional A general description of the device that produces the mechanical or electrical power that runs the equipment. For example diesel engine, electric motor, gas turbine etc.
elevation over mean sea level Number metre Optional Plant elevation over mean sea level.
environmental location Text — Optional The environmental installation location of the equipment.
erosion due to Text — Optional Description of the cause of the expected erosion.
explosion protection gas group Text — Optional Specify the gas group classification of the physical object in accordance with IEC/EN 60079-20
explosion protection temperature class Text — Optional Specify the temperature classification of the physical object in accordance with CENELEC EN50014
explosion protection zone Text — Optional Specify the hazardous zone in which the functional or physical object is expected to operate.
explosion rated item Boolean — Optional An indicator that an equipment has been classified as safe for use in hazardous areas
flat surface provision for mounting accelerometers only Text — Optional Specify if only flat surfaces for mounting portable magnetic type accelerometers are required.
flat surface provision for mounting vibration probes only Text — Optional Specify if only flat surface provision for mounting portable magnetic type vibration proximity probes are required.
floating applications motion design criteria Text — Optional Specify the metocean and floating facility data of the location where the equipment will be installed.
fluid name Text — Optional The name of the product in liquid or gas phase.
fouling factor Text — Optional The amount of fouling in the liquid.
grade (underside of pump mounting plate or top of foundation) elevation Text inch Optional Specify the grade (underside of pump mounting plate or top of foundation) elevation at which the proposed pump is to be installed.
grease grade Text — Optional Is a specification which describes the lubricant grease grade.
grease type Text — Optional Is a specification which describes the lubricant grease type.
H2S concentration Number part per million Optional Specifies the level of H2S in the fluid.
hardened sleeves under line shaft bearings Text — Optional Specify if hardened sleeves under line shaft bearings are required.
hardness testing of parts, welds and heat-affected zones Text — Optional Specify is hardness testing of parts, welds and heat-affected zones is required.
hazardous area certification standard Text — Optional The standard used to Specify hazardous areas.
head column material Text — Optional The material from which the head column is constructed.
heat tracing Boolean — Optional Tracing by supply of heat
heat tracing and insulation location Text — Optional Specify where heat tracing and insulation is to be applied.
heat tracing supplied by Text — Optional Specify who is responsible for supplying heat tracing.
heating jacket required Text — Optional Specify if a heating jacket is required..
heating tracing specification Text — Optional Is a specification which describes the heating tracing.
ignition hazard assessment Text — Optional Specify if ignition hazard assessment is required.
immersed Boolean — Optional Specify if the functional or physical object can be immersed or not.
impeller material Text — Optional The material from which the impeller is constructed.
impeller type Text — Optional Specify the pump impeller type.
impeller wear component hardness Text — Optional The hardness of the material from which the impeller wear component is constructed.
impeller wear component material Text — Optional The material from which the impeller wear component is constructed.
impeller wear component type Text — Optional Specify the impeller wear component type required for the proposed pump.
individual pump flow control Boolean — Optional Specify if the pump has an individual flow control.
inducer material Text — Optional The material from which the inducer is constructed.
inlet flange facing Text — Optional Specify the inlet flange facing.
inlet flange rating Text — Optional Is a possessed aspect being a design pressure of a flange.
instantaneous start up requirement Text — Optional Specify whether instantaneous start-up is required.
insulation required Boolean — Optional Specify if insulation is required or not.
insulation specification Text — Optional Is a specification which describes the insulation.
insulation supplied by Text — Optional Specify who is responsible for supplying insulation.
line shaft bearing lube Text — Optional Specify the type of line shaft bearing lubrication required.
line shaft bearing material Text — Optional The material from which the line shaft bearing is constructed.
line shaft configuration Text — Optional Specify the line shaft configuration required.
line shaft connection Text — Optional Specify the type of line shaft connection required.
line shaft hard facing material Text — Optional The material from which the line shaft hard facing is constructed.
line shaft material Text — Optional The material from which the line shaft is constructed.
line shaft sleeves material Text — Optional The material from which the line shaft sleeve is constructed.
liquid name Text — Optional The name of the product in liquid phase.
liquid type Text — Optional Specify the liquid characteristics.
location heated or unheated Text — Optional Specify if the location heated or unheated.
location in or outdoor Text — Optional The equipment location and climate condition.
location mounting Text — Optional Specify the level at which the equipment will be installed.
location sunlight protection Text — Optional The equipment's protection to sunlight exposure.
low liquid level elevation Number millimetre Optional Specify the process liquid low level elevation.
lower limit ambient operating temperature Number degree celsius Optional The temperature which is the lowest ambient temperature at which a functional or physical object is expected to operate.
lower limit design temperature Number degree celsius Optional The lowest temperature at which a functional or physical object is designed.
lower limit dynamic sealing pressure Number bar gauge Optional The lowest dynamic viscosity of the fluid in liquid phase at which a functional or physical object is expected to operate normally.
lower limit flow net positive suction head available Number metre Optional NPSHA that is available for a particular pumping system at lowest flow condition.
lower limit liquid density Number kilogram per cubic metre Optional A liquid density which is the lowest density at which a functional or physical object is expected to operate.
lower limit operating heating steam pressure Number bar gauge Optional The pressure which is the lowest heating steam pressure at which a functional or physical object is expected to operate.
lower limit operating heating steam temperature Number degree celsius Optional The temperature which is the lowest heating steam temperature at which a functional or physical object is expected to operate.
lower limit operating inlet pressure Number PRESS Optional The pressure which is the lowest pressure at which a functional or physical object is expected to operate at its inlet connection.
lower limit operating instrument air pressure Number bar gauge Optional The pressure which is the lowest instrument air pressure at which a functional or physical object is expected to operate.
lower limit operating liquid dynamic viscosity Number centipoise Optional The lowest dynamic viscosity of the fluid in liquid phase at which a functional or physical object is expected to operate normally.
lower limit operating outlet pressure Number PRESS Optional The pressure which is the lowest pressure at which a functional or physical object is expected to operate at its outlet connection.
lower limit operating suction pressure Number bar Optional The suction pressure which is the lowest pressure at which a functional or physical object is expected to operate.
lower limit operating temperature Number degree celsius Optional A temperature that is the lowest temperature at which a functional or physical object is expected to operate.
lower limit operating volume flow rate Number cubic metre per hour Optional A volume flow rate that is the lowest volume flow rate at which a functional or physical object is expected to operate.
lower limit seal design temperature Number degree celsius Optional The lowest dynamic viscosity of the fluid in liquid phase at which a functional or physical object is expected to operate normally.
lower limit site ambient temperature Number degree celsius Optional The temperature which is the lowest ambient temperature at the site where the physical object is expected to operate.
lower limit site relative humidity Number percent Optional The humidity which is the lowest relative humidity at the site where the physical object is expected to operate.
lower limit specific heat Number SPHCAP Optional The lower specific heat limit that describes how much energy is needed to change the temperature of a material.
lower limit static sealing pressure Number bar gauge Optional The lowest dynamic viscosity of the fluid in liquid phase at which a functional or physical object is expected to operate normally.
lower limit vapour pressure Number bar absolute Optional A vapour pressure which is the lowest vapour pressure at which a functional or physical object is expected to operate.
lower upper operating instrument air pressure Number bar gauge Optional The pressure which is the highest instrument air pressure at which a functional or physical object is expected to operate.
machined and studded connections Text — Optional Specify whether machined and studded connections are required for the proposed pump casing.
material hardness standard Text — Optional Specify the applicable material hardness standard.
minimum design metal temperature Number degree celsius Optional Is a temperature that is the lowest at which a significant load can be applied. Typically applied to a pressure vessel. Defined by the ASME Code, Section VIII, Division 1, paragraph UG-20 (see Section 3).
monitors and cables supplied by Text — Optional Specify who is responsible for supplying and installing vibration and temperature instrument monitors and cables.
net positive suction head available Number metre Optional NPSH for a particular pumping system at a certain flow rate and temperature.
nonwetted pressure-retaining fasteners material Text — Optional The material from which the nonwetted pressure-retaining fastener is constructed.
normal flow net positive suction head available Number metre Optional NPSHA that is available for a particular pumping system at normal flow condition.
normal operating dynamic viscosity Number centipoise Optional The dynamic viscosity at which a functional or physical object is expected to operate normally.
normal operating inlet pressure Number bar absolute Optional An inlet pressure at which a functional or physical object is expected to operate normally.
normal operating inlet temperature Number degree celsius Optional The temperature at which a functional or physical object is expected to operate normally at its inlet connection.
normal operating outlet pressure Number bar absolute Optional The pressure at which a functional or physical object is expected to operate normally at its outlet connection.
normal operating suction pressure Number bar Optional The normal suction pressure at which a functional or physical object is expected to operate.
normal operating temperature Number degree celsius Optional A temperature at which a functional or physical object is expected to operate normally.
normal operating volume flow rate Number VOLFLO Optional The volume flow rate at which a functional or physical object is expected to operate normally.
normal specific heat Number SPHCAP Optional The specific heat limit that describes how much energy is needed to change the temperature of a material.
normal volume flow rate Number cubic metre per hour Optional A volume flow rate a functional or physical object is designed to deliver under normal conditions.
nozzle load Text — Optional The net forces and moments exerted on equipment nozzle.
NPSHA available at 120% of rated flow Number metre Optional NPSHA that is available for a particular pumping system at 120% of rated flow condition.
NPSHA datum Text — Optional Specify the reference datum for the pump suction conditions, including NPSH3.
NPSHa-NPSH3 margin at rated flow Number metre Optional The net positive suction head available at rated flow minus the NPSH3; the net positive suction head available to a pump under test at a the rated flow when the pump head is decreased by 3 percent as a result of cavitation caused by a decreasing available suction head.
NPSHa-NPSH3 margin in allowable operating region Number metre Optional The net positive suction head in the operating range of flow minus the NPSH3; the net positive suction head available to a pump under test at a the operating range of flow when the pump head is decreased by 3 percent as a result of cavitation caused by a decreasing available suction head.
number of accelerometers Number piece Optional Specify the number of accelerometers required.
number of electrical phases Number piece Optional The number of phases in an electrical distribution system.
number of starts Number per hour Optional The number of starts of the machine per unit of time.
number of temperature probes per radial bearing Number piece Optional Specify the number of temperature probes per radial bearing required.
number of units required Number piece Optional Specify the number of units required.
number of vibration probes per radial bearing Number piece Optional Specify the number of vibration proximity probes per radial bearing required.
OH3 back-pullout lifting device required Text — Optional Specify if device for back-pullout and lifting of a OH3 type pump is required.
oil mist reclassifiers supplied by Text — Optional Specify who is responsible for supplying oil mist directional reclassifiers for the proposed pump.
oil viscosity ISO grade Text — Optional Specify the oil viscosity ISO grade.
one-event-per-revolution probe (key phasor) Text — Optional Specify if a one-event-per-revolution probe (key phasor) is required.
operation continuous intermittent Text — Optional Specifies if the equipment is working continuously or in an intermittent way.
operation single/parallel Text — Optional Specifies if the equipment is working alone or with similar equipment in parallel.
orientation Text — Optional The mount position of an equipment such as horizontal, vertical or submerged
outlet flange facing Text — Optional Specify the outlet flange facing.
outlet flange rating Text — Optional Is a possessed aspect being a design pressure of a flange.
particle concentration Number part per million Optional Average solid particle concentration in fluid.
particle size Number micrometre Optional Average solid particle size in fluid.
process wetted fasteners material Text — Optional The material from which the process wetted fasteners is constructed.
provision for mounting temperature probes only Text — Optional Specify if only provision for mounting temperature probes is required.
pump baseplate mounting Text — Optional Specify the required baseplate mounting for the proposed pump.
pump baseplate sized to accommodate seal piping systems Text — Optional Specify if the proposed pump baseplate is required to be sized to accommodate seal piping systems.
pump baseplate type Text — Optional Specify the required baseplate type for the proposed pump.
pump bowl maximum allowable working pressure Number bar gauge Optional The pump bowl MAWP.
pump casing type Text — Optional The type and shape of the casing.
pump column maximum allowable working pressure Number bar gauge Optional The pump column MAWP.
pump construction material Text — Optional Specify the material from which the pump is constructed according to API 610, Table H.1.
pump discharge head maximum allowable working pressure Number bar gauge Optional The pump discharge head MAWP.
pump impact test Text — Optional Specify the impact test standard required for the proposed pump.
pump material inspection requirement Text — Optional Specify the material inspection requirements for the proposed pump.
pump mechanical seal primary plan Text — Optional Specify the mechanical seal primary piping plan required for the proposed pump.
pump mechanical seal primary plan construction Text — Optional Specify the mechanical seal primary piping plan construction required for the proposed pump.
pump mechanical seal secondary piping plan Text — Optional Specify the mechanical seal secondary piping plan required for the proposed pump.
pump mounting method Text — Optional The way the pump is mounted.
pump operation type Text — Optional Specify the pump operational mode.
pump service type Text — Optional Continuous or Intermittent service.
pump start-up mode Text — Optional Specify the pump start-up mode.
pump suction barrel or can maximum allowable working pressure Number bar gauge Optional The pump suction barrel or can MAWP.
pump thrust bearing location Text — Optional Specify the location for the thrust bearing.
pump type Text — Optional The pump type selected on a pump's specification sheet
purpose of insulation Text — Optional Specify the purpose of insulation.
radial bearing type Text — Optional Specify the driver radial bearing type.
rated discharge pressure Number bar Optional The discharge pressure to which an installed item is rated.
rated flow net positive suction head available Number metre Optional NPSHA that is available for a particular pumping system at rated flow condition.
rated frequency Number hertz Optional An electrical frequency of a machine at rated output
rated hydraulic power Number horsepower Optional The rated power that the pumping action takes.
rated input voltage Number volt Optional Input voltage for which the equipment is constructed
rated operating differential head pressure Number bar Optional The differential pressure at which a functional or physical object is expected to operate normally.
rated operating differential pressure Number bar Optional The rated differential pressure at which a functional or physical object is expected to operate.
rated operating suction pressure Number bar Optional The rated suction pressure at which a functional or physical object is expected to operate.
rated operating temperature Number degree celsius Optional The rated temperature at which a functional or physical object is expected to operate.
rated relative density Number kilogram per cubic metre Optional The rated ratio of the density (mass of a unit volume) of a substance to the density of a given reference material.
rated speed Number revolution per minute Optional The rotational speed a functional or physical object is designed to deliver under specified conditions.
rated volume flow rate Number cubic metre per hour Optional A volume flow rate a functional or physical object is designed to deliver at specified conditions.
reduced-hardness materials Text — Optional Specify if reduced-hardness materials are required.
repair and heat treatment records Text — Optional Specify whether the vendor is required to keep repair and heat treatment records.
review and acceptance of thrust bearing size Text — Optional Specify if the trust bearing size for the proposed pump is required to be reviewed and accepted. Applicable to API pump types BB1, BB2 and BB3.
rolling element bearing life calculations Text — Optional Specify if the rolling element bearing life calculations are required for the bearing arrangement.
shaft enclosing tube material Text — Optional The material from which the shaft enclosing tube is constructed.
shaft flexibility index reported by vendor Text — Optional Specify if the shaft flexibility index (SFI) is to be reported by vendor.
shaft material Text — Optional The material from which the shaft is constructed.
shrink fit limited movement impellers Text — Optional Specify if shrink fit limited movement impellers are required.
special coating requirement for impellers and other wetted parts Text — Optional Specify if special coating for impellers and other wetted parts are required.
special weather protection Text — Optional Required weather protection like roof or winterization.
stainless steel plate, thickness 0.2 in. (5 mm) minimum, under all pump feet Text — Optional Specify if stainless steel plates, thickness 0.2 in. (5 mm) minimum, under all pump feet  are required for the proposed pump.
strainer material Text — Optional The material from which the strainer is constructed.
strainer type Text — Optional Specify the strainer type.
suction barrel/can material Text — Optional The material from which the suction barrel/can is constructed.
suction nozzle position Text — Optional Specify the suction nozzle flange position.
sump diameter Number millimetre Optional Specify the diameter of the sump in which the proposed pump will be installed.
sump floor elevation Number millimetre Optional Specify the sump floor elevation.
temperature gauges requirements Text — Optional Specify if temperature gauges are required.
temperature probe mounting location Text — Optional Specify the required mounting locations for the temperature probes.
temperature probe requirement Text — Optional Specify if temperature probes are required.
test medium Text — Optional The medium used for testing purpose.
test pressure Number bar gauge Optional A pressure to which an object should be subjected to test for leakage and structural integrity.
thermal insulation class Text — Optional The class of electrical insulation used by a physical object.
thread specification Text — Optional Is a specification which describes the threads.
threaded provision for mounting accelerometers only Text — Optional Specify if only threaded provision for mounting accelerometers is required.
threaded provision for mounting vibration probe only Text — Optional Specify if only threaded provision for mounting vibration proximity probes is required.
thrust bearing type Text — Optional Specify the thrust bearing type.
total dissolved salts Number part per million Optional The amount of dissolved salts.
type of level control Text — Optional Specify the type of level control required.
unusual service conditions Text — Optional Specify if unusual service conditions not covered in purchase order documents apply.
upper limit allowable sound pressure level Number decibel Optional The highest allowable acoustic wave strength, which is the local pressure deviation from the ambient (average or equilibrium) atmospheric pressure, caused by a sound wave.
upper limit ambient operating temperature Number degree celsius Optional The temperature which is the highest ambient temperature at which a functional or physical object is expected to operate.
upper limit design cooling water inlet pressure Number bar gauge Optional The pressure which is the highest cooling water inlet pressure at which a functional or physical object is designed for.
upper limit design cooling water inlet temperature Number degree celsius Optional The temperature which is the highest cooling water inlet temperature at which a functional or physical object is designed for.
upper limit design cooling water pressure Number bar gauge Optional The pressure which is the highest cooling water pressure at which a functional or physical object is designed for.
upper limit design pressure Number bar gauge Optional The highest pressure at which a functional or physical object is designed for.
upper limit design temperature Number degree celsius Optional The highest temperature at which a functional or physical object is designed.
upper limit dynamic sealing pressure Number bar gauge Optional The highest dynamic sealing pressure at which a functional or physical object is expected to operate normally.
upper limit flow net positive suction head available Number metre Optional NPSHA that is available for a particular pumping system at highest flow condition.
upper limit liquid density Number kilogram per cubic metre Optional A liquid density which is the highest density at which a functional or physical object is expected to operate.
upper limit operating cooling water inlet temperature Number degree celsius Optional The temperature which is the highest cooling water inlet temperature at which a functional or physical object is expected to operate.
upper limit operating discharge pressure Number bar Optional The discharge pressure which is the highest pressure at which a functional or physical object is expected to operate.
upper limit operating heating steam pressure Number bar gauge Optional The pressure which is the highest heating steam pressure at which a functional or physical object is expected to operate.
upper limit operating heating steam temperature Number degree celsius Optional The temperature which is the highest heating steam temperature at which a functional or physical object is expected to operate.
upper limit operating inlet pressure Number bar absolute Optional The pressure which is the highest pressure at which a functional or physical object is expected to operate at its inlet connection.
upper limit operating liquid dynamic viscosity Number centipoise Optional The highest dynamic viscosity of the fluid in liquid phase at which a functional or physical object is expected to operate normally.
upper limit operating outlet pressure Number PRESS Optional The pressure which is the highest pressure at which a functional or physical object is expected to operate at its outlet connection.
upper limit operating pressure Number bar gauge Optional A pressure which is the highest pressure at which a functional or physical object is expected to operate.
upper limit operating suction pressure Number bar Optional The pressure which is the highest pressure at which a functional or physical object is expected to operate at its inlet connection.
upper limit operating temperature Number degree celsius Optional A temperature that is the highest temperature at which a functional or physical object is expected to operate.
upper limit operating volume flow rate Number cubic metre per hour Optional A volume flow rate that is the highest volume flow rate at which a functional or physical object is expected to operate.
upper limit relative humidity Number percent Optional The highest relative humidity at which a functional or physical object is designed for.
upper limit seal design temperature Number degree celsius Optional The highest seal design temperature at which a functional or physical object is expected to operate normally.
upper limit site ambient temperature Number degree celsius Optional The temperature which is the highest ambient temperature at the site where the physical object is expected to operate.
upper limit sound power level Number decibel Optional The highest sound pressure level at which a functional or physical object is designed.
upper limit specific heat Number SPHCAP Optional The upper specific heat limit that describes how much energy is needed to change the temperature of a material.
upper limit static sealing pressure Number bar gauge Optional The highest static sealing pressure at which a functional or physical object is expected to operate normally.
upper limit vapour pressure Number bar absolute Optional A vapour pressure which is the highest vapour pressure at which a functional or physical object is expected to operate.
vapour pressure at rated temperature Number bar absolute Optional The vapour pressure rated temperature to which an installed item is rated.
vent valve supplied by Text — Optional Specify who is responsible for supplying the vent valve.
vibration probes mounting location Text — Optional Specify the required mounting locations for the vibration proximity probes.
vibration probes requirement Text — Optional Specify if vibration proximity probes are required.
wear parts hardnesses Text — Optional The hardness of the material from which the wear parts is constructed.
API baseplate number Text — Optional Specify the API baseplate number for the proposed pump.
ATEX category Text — Optional Specify in which category the physical object is divided in accordance with the directive 94/9/EC.
ATEX explosive atmosphere Text — Optional Specify in which explosive atmosphere the physical object is divided in accordance with the directive 94/9/EC.
ATEX group Text — Optional Specify in which group the physical object is divided in accordance with the directive 94/9/EC.
bearing lubrication Text — Optional The method of lubrication of the bearings.
direction of rotation Text — Optional Specify the direction of rotation of the functional or physical object.
drain nominal size Number millimetre Optional The nominal size of the drain.
dry weight Number kilogram Optional A weight of an object excluding any operating or process fluids.
efficiency Number percent Optional Ratio of an output power to an input power
end of allowable operating flow region Number cubic metre per hour Optional The end of the range of allowable flow in operating conditions.
end of operating flow region Number cubic metre per hour Optional The end of the range of flow in operating conditions.
explosion protection concept Text — Optional Specify the identification of electrical equipment's explosion protection and type of ignition protection in accordance with IEC/EN 60079-0.
explosion protection examination certificate number Text — Optional The examination certificate number for the physical object issued by a notified body.
explosion protection material group Text — Optional Specify for purposes of testing, approval, and area classification, various air mixtures (not oxygen-enriched) grouped in accordance with 500.6(A) and (B).
explosion protection notified body Text — Optional The name of the nationally accredited approval body that has issued the examination certificate for the physical object.
grade to first stage impeller centerline dimension Number millimetre Optional Specify the grade to the proposed pump first stage impeller centerline dimension.
grade to liquid minimum submergence level dimension Number millimetre Optional Specify the grade to pump process liquid minimum submergence level dimension.
grade to top of pump discharge connection dimension Number millimetre Optional Specify the grade to top of proposed pump discharge connection dimension.
heating medium Text — Optional Specify the heating medium.
impeller diameter Number millimetre Optional The size of the impeller in a rotating machinery
ingress protection Text — Optional Specify the degree of ingress protection for the physical object in accordance with IEC/EN 50629 or NEMA, UL and CSA type rating.
inlet flange size Number millimetre Optional Is a diameter by which a quantitative diameter is referred to. Typically a standardized value with defined tolerances.
line shaft bearing quantity Number piece Optional Specify the quantity of line shaft bearings required.
lower limit allowable temperature Number TEMP Optional The temperature which is the lowest allowed.
lower limit diameter Number millimetre Optional The designed intercept made by the circumference on a straight line through the centre of a circle.
lower limit stable flow Number cubic metre per hour Optional Minimum flow that can be sustained stably.
lower limit thermal mass flow Number cubic metre per hour Optional Minimum mass flow measured by a thermal mass flow element.
net positive suction head required Number LENGTH Optional Minimum NPIP required by the pump to achieve the required performance with the specified fluid at any specified point, as determined by Vendor. NPIP shall always include acceleration losses.
NPSH3 at 120 % of flow Number metre Optional The net positive suction head available to a pump under test at a 120% of the rated flow when the pump head is decreased by 3 percent as a result of cavitation caused by a decreasing available suction head.
NPSH3 at rated flow Number metre Optional The net positive suction head available to a pump under test at a the rated flow when the pump head is decreased by 3 percent as a result of cavitation caused by a decreasing available suction head.
number of stages Number piece Optional The number of stages a fluid goes through from input to output (stages in a compressor, stages in a column etc.)
number of vanes Number piece Optional The number of vanes.
operating weight Number kilogram Optional A weight that is the weight an object is expected to have during operation, i.e. including process fluids etc.
outlet flange size Number millimetre Optional Is a diameter by which a quantitative diameter is referred to. Typically a standardized value with defined tolerances.
pressure casing vent size Number millimetre Optional The nominal size of the casing vent.
proposal curve best efficiency point flow (at rated impeller diameter) Number cubic metre per hour Optional Flow at Best Efficiency Point (BEP) of the proposed curve at rated impeller diameter.
proposal for pump performance curve number Text — Optional The graphically designed performance of a centrifugal pump (flowrate/head); proposed curve number.
pump length (grade to underside of pump inlet bell or strainer dimension) Number millimetre Optional Specify the proposed pump length (grade to underside of pump inlet bell or strainer dimension) below grade.
pump size Text — Optional Specify the size of the pump.
rated inlet pressure Number PRESS Optional The pressure to which an installed item is rated
rated output power Number horsepower Optional A power that is the power a motor has been designed to deliver under specified conditions.
rated power consumption Number kilowatt Optional A power consumption at rated conditions.
seal type Text — Optional The type of seal used to prevent process fluids to evacuate across the shaft on a rotating machinery / wellhead housing /tree interface seal e.g. VX gasket, VX-V2 gasket
shaft flexibility index Text — Optional Specify the shaft flexibility index (SFI).
specific pump speed Text — Optional The rotational speed which is the specific rotational speed for the pump.
specific pump suction-specific speed Number revolution per minute Optional The rotational speed which is the suction-specific rotational speed for the pump.
start of allowable operating flow region Number cubic metre per hour Optional The beginning of the range of allowable flow in operating conditions.
start of operating flow region Number cubic metre per hour Optional The beginning of the range of flow in operating conditions.
total weight Number kilogram Optional A weight that is a sum of the weights of identified parts of an assembly.
upper limit allowable pressure Number PRESS Optional The pressure which is the highest allowed.
upper limit allowable speed Number revolution per minute Optional The speed which is the highest allowed.
upper limit allowable temperature Number TEMP Optional The temperature which is the highest allowed.
upper limit diameter Number millimetre Optional The upper limit intercept made by the circumference on a straight line through the centre of a circle.
upper limit head at rated impeller Number metre Optional The head that is the highest that can be obtained for the rated impeller.
upper limit power at rated impeller Number horsepower Optional The power that is the highest allowed for the rated impeller.
warm-up or cool-down line for instantaneous start up Text — Optional Specify whether a separate warm-up or cooldown line is required for instantaneous start-up of the pump.

Suggest a change

Opens a pre-filled GitHub issue on the COPI repo — nothing is sent until you submit it there.