Top drives
ISO 14224
Equipment — Well intervention
ID: equip_TD
| URI: https://www.iso.org/standard/64076.html
No definition available.
Properties / Attributes (17)
| Name | Data Type | Unit / Valid values | Required | Definition |
|---|---|---|---|---|
| Type of driver | — |
Electric, hydraulic | Required | Specify type |
| Number of drives | — |
Number | Required | Specify number |
| (applicable for hydraulic drives only) | — |
— | Required | |
| Hydraulic power requirements | — |
Pascal (bar) | Required | Pressure |
| Motor category | — |
Induction, synchronous | Required | Specify type |
| (applicable for electric drives only) | — |
— | Required | |
| Electrical supply requirements | — |
Volt | Required | Voltage |
| Rated power | — |
Kilowatt | Required | Max. output |
| Normal operating power | — |
— | Required | |
| Speed | — |
Revolutions per minute | Required | Max. speed |
| Torque | — |
— | Required | |
| Pressure utilities | — |
Pascal (bar) | Optional | Hydraulic pressure |
| Retractable dolly frame | — |
Yes/no | Optional | Specify |
| Mud pressure capacity | — |
Pascal (bar) | Optional | Pressure |
| Inside BOP design pressure | — |
— | Optional | |
| Torque wrench capacity | — |
Millimetres | Optional | Diameter |
| Failure modes | 12 failure modes — click to expand
AIR
Abnormal instrument reading
ELU
External leakage - utility medium
ERO
Erratic output
FTS
Failure to start on demand
HIO
High output
INL
Internal leakage
LOO
Low output
NOI
Noise
OHE
Overheating
OTH
Other
SER
Minor in-service problems
STP
Failure to stop on demand
|
|||