Core Ontology for Petroleum Installations · INF-UFRGS-Ontologies · CNPq INF-UFRGS-ENERGIA inf.ufrgs.br/ontologies/copi dee69df

Surface wellhead and X-mas trees

ISO 14224 Equipment — Well completion

ID: equip_XD  |  URI: https://www.iso.org/standard/64076.html

No definition available.

Properties / Attributes (16)
Name Data Type Unit / Valid values Required Definition
Well identification no — Specify Required Well identification no - operator
Well function — Production, injection, disposal Required description
Design pressure — Pascal (bar) Required Pressure rating of wellhead and
Mudline suspension system — Yes/no Optional Define whether a mudline system suspension exists
Type of well — Offshore, SPAR, TLP, Onshore, l, HPHT, Required Type of tie-back solution
Wellhead flowing pressure — Psi Optional Representative operational wellhead flowing pressure
Wellhead flowing temperature — Degrees Celsius Optional Representative operational wellhead flowing temperature
Well flow rate — Specify Required Representative well flow rate (production or injection)
Fluid produced / injected — Air, chemicals, condensate, crude oil, flare gas, freshwater, fuel gas, gas, gas+condensate, gas+oil, gas+oil+water, combined hydrocarbons, methanol, nitrogen, oil, oil+water, oily water, sea Required Fluid produced / injected
Control principle — water, treaded sea water, steam, unknown, water/glycol Required Defines the control principle for
Fluid corrosiveness — Benign, clean, moderate, severe, unknown Required Fluid corrosiveness
Fluid erosiveness — Benign, clean, moderate, severe, unknown Required Erosiveness of the well fluid
Valve application — Swab (SV), Production wing (PWV), Required X-mas tree valve function
Valve design class — Kill (KV), Upper master (UMV), Lower master (LMV), Annulus (AV) Required Type of valve design
Piston, Ram, Swing — — Optional
Failure modes
17 failure modes — click to expand
BRD Breakdown CLW Control-line-to-well communication ELP External leakage - process medium ELU External leakage - utility medium ERO Erratic output FTC Failure to close on demand FTF Failure to function on demand FTO Failure to open on demand ILP Internal leakage - process medium ILU Internal leakage - utility medium LOO Low output OHE Overheating OTH Other PLU Plugged/ choked SPO Spurious operation STD Structural deficiency UNK Unknown

Suggest a change

Opens a pre-filled GitHub issue on the COPI repo — nothing is sent until you submit it there.