Core Ontology for Petroleum Installations · INF-UFRGS-Ontologies · CNPq INF-UFRGS-ENERGIA inf.ufrgs.br/ontologies/copi dee69df

Valves

ISO 14224 Equipment — Safety and control

ID: equip_VA  |  URI: https://www.iso.org/standard/64076.html

No definition available.

Properties / Attributes (25)
Name Data Type Unit / Valid values Required Definition
Main function — Flow control, on/off, non-return, Pressure relief, instrument or hydraulic control Required Main functional category
Application — Annulus (X-mas tree), blowdown, bypass, injection, Required Specify function in the process
Where mounted — X-over, Deluge, ESD, ESD/PSD, PSD, HIPPS, swab, wing, relief, control, choke Required Equipment on which the valve is installed
Size — mud process, utility, living quarter, air inlet, riser Required Internal diameter
Fluid handled — Millimetres (inches) Required Main fluid only
Fluid temperature — Degrees Celsius Optional Operating temperature main fluid a
Fluid corrosiveness/ erosiveness — Benign, moderate, severe Optional Classify as shown in the footnote
Shut-off pressure — Pascal (bar) Optional Maximum differential pressure when valve closed (design)
Valve material — Carbon steel (CS), stainless steel (SST), duplex, Required Type
Stem sealing — Stuffing box, duplex, lip seal, O-ring Required Type
Seat design — Soft seated, metal-to-metal seated Required Type of seat design
Actuation principle — Single-acting, double-acting, actuation by line/process pressure, actuation by gravity Optional Actuator operating principle
Actuation – opening — Electrical, hydraulic, pneumatic, mechanical Required Type of actuation force
Actuation – closing — Electrical, hydraulic, pneumatic, mechanical Optional Type of actuation force
Manufacturer – actuator — Specify Optional Name of actuator manufacturer
Manufacturer – pilot valve — Specify Optional Name of pilot-valve manufacturer
Manufacturer – solenoid valve — Specify Optional Name of solenoid-valve manufacturer
Pilot-valve configuration — Specify, e.g. 1 × 3/2 (= single 3/2 pilot valve), Optional Number and configuration (applicable for pilot-operated valves only)
Fail-safe principle pilot valve — Energized, de-energized Optional Fail-safe principle
Solenoid-valve configuration — Specify, e.g. 1 × 3/2 (= single 3/2 pilot valve), Optional Number and configuration (applicable for solenoid-operated valves only)
Fail-safe principle solenoid valve — 2 × 4/3 (= double 4/3 pilot valve) Optional Fail-safe principle
Valve fail-safe position — Fail-open, Fail-close, Fail-as-is Required Fail-safe position
Trim type — Noise reduction, anti-cavitation, multi-stage, single-stage Required Type (applicable for control valves only)
Valve leakage — ISO 5208:2015, Annex A, Table 4 Required Specify according to applicable reference
Failure modes
14 failure modes — click to expand
AIR Abnormal instrument reading DOP Delayed operation ELP External leakage - process medium ELU External leakage - utility medium FTC Failure to close on demand FTO Failure to open on demand HIO High output INL Internal leakage LCP Leakage in closed position LOO Low output NOI Noise SER Minor in-service problems STD Structural deficiency VIB Vibration

Suggest a change

Opens a pre-filled GitHub issue on the COPI repo — nothing is sent until you submit it there.