Core Ontology for Petroleum Installations · INF-UFRGS-Ontologies · CNPq INF-UFRGS-ENERGIA inf.ufrgs.br/ontologies/copi dee69df

Input devices

ISO 14224 Equipment — Safety and control

ID: equip_IP  |  URI: https://www.iso.org/standard/64076.html

No definition available.

Properties / Attributes (12)
Name Data Type Unit / Valid values Required Definition
Functional characteristics — — Optional
Location on installation — Drill floor, wellhead, process, auxiliary, mud processing, power generation, Required Where installed
Application — utility, control room, auxiliary room, living quarter Required Where applied
Item characteristics — — Optional
Category — Transmitter, transducer, switch, pushbutton Required Main category
Sensing principle — Bonded strain, semiconductor, strain, Required Applicable for pressure sensors only
Sensor voting, out of — Y yy Required At least out of the totkal numYber, , of sensors shall provide signal to initiate
(only as relevant) — = “ ” (integer) Required
Fault tolerance — Yes/No Required entered; if no voting, leave blank.
Detector communication — Conventional, addressable (one-way), smart (two-way) Optional Type
Self-test feature — No self-test, automatic loop test, built-in test, combined Required Degree of self-testing
Failure modes
8 failure modes — click to expand
ELP External leakage - process medium ELU External leakage - utility medium ERO Erratic output FTF Failure to function on demand HIO High output LOO Low output NOO No output SER Minor in-service problems

Suggest a change

Opens a pre-filled GitHub issue on the COPI repo — nothing is sent until you submit it there.