Core Ontology for Petroleum Installations · INF-UFRGS-Ontologies · CNPq INF-UFRGS-ENERGIA inf.ufrgs.br/ontologies/copi dee69df

Pumps

ISO 14224 Equipment — Rotating

ID: equip_PU  |  URI: https://www.iso.org/standard/64076.html

No definition available.

Properties / Attributes (51)
Name Data Type Unit / Valid values Required Definition
Type of driver — Specify Required Equipment class, type and identification code
Fluid handled — Oil, gas, condensate, freshwater, steam, sea water, crude oil, oily water, flare gas, fuel gas, water/glycol, methanol, nitrogen, chemicals, hydrocarbon-combined, gas/oil, gas/condensate, oil/water, gas/ Required Type
Fluid corrosive/erosive — cement, other Optional a
Application – pump — Booster, supply, injection, transfer, lift, dosage, disperse, cooling, drilling, other Optional Where applied
Pump – design — Axial, radial, composite, diaphragm, Required Design characteristic
Power – design — Kilowatt Required Design/rated power of pump
Utilization of capacity — Percent Required Normal operating/design capacity
Suction pressure – design — Pascal (bar) Optional Design pressure
Discharge pressure – design — Pascal (bar) Required Design pressure
Speed — Revolutions per minute or strokes per minute Optional Design speed
Number of stages — Number Optional Centrifugal: number of impellers (in all stages)
Body type — Barrel, split case, axial split, cartridge, Optional Barrel, split casing, etc.
Shaft orientation — Horizontal, vertical Optional
Shaft sealing — Mechanical, oil seal, dry gas, packed, Optional Type
Transmission type — gland, dry seal, labyrinth, combined Optional Type
Coupling — Fixed, flexible, hydraulic, magnetic, Optional Coupling
Environment — disconnect Optional Submerged or dry-mounted
Pump cooling — Yes/No Optional Specify if separate cooling system is
Radial bearing — Antifrictional, journal, magnetic Optional Type
Thrust bearing — Antifrictional, journal, magnetic Optional Type
Well identification number — Number or name Required Operator description
Model type — Onshore well Required Type of application
ESP Application — Topsides well (dry tree completion) Required
Fluid corrosiveness — Horizontal pump system (HPS) Required Neutral, Sweet, Sour
Shaft power rating — Horse power HP Required All, where applicable
Shaft coupling rating — Horse power HP Required All, where applicable
Maximum flow capacity — Blpd Optional Bolt on discharge head
Design performance — Pump curve Optional Pump and gas handler
Maximum GVF rating — % Optional Pump and gas handler
Pump stage thrust — Pounds, lbs Required Pump and gas handler
Housing pressure rating — Psi Required Pump and gas handler
Maximum flow capacity rating — Blpd Optional Bolt on intake
Design performance curve — Performance Curve Optional Mechanical gas separator
Volume contraction capacity — Litres Required Seal chamber section
Operation deviation limits — Specify [numeric value] Required Seal chamber section
Thrust load bearing capacity — Pounds, lbs Required Seal chamber section
Minimum operating speed for thrust bearing — Revolutions per minute, rpm, or Frequency Optional Seal chamber section
Number and severity of — Specify Required Seal chamber section
Horsepower requirement — — Required
Motor performance parameters — Performance curve Required Motor
Motor voltage for minimum current — Amps Required Motor
Motor winding temperature rise — Degrees Celsius Required Motor
Motor operating internal temperature limits — Degrees Celsius Required Motor
Locked rotor current, — Amps Required Motor
Voltage rating — Volt Required Power cable and MLE
Temperature rating — Degrees Celsius Required Power cable and MLE
Ampacity coefficients — Specify [numeric value] Required Power cable and MLE
Conductor Size — Millimetres Required Power cable and MLE
Acceptable minimum — Metres Required Power cable and MLE
Differential pressure performance — Psi Required Pothead
Failure modes
18 failure modes — click to expand
AIR Abnormal instrument reading BRD Breakdown ELF External leakage - fuel ELP External leakage - process medium ELU External leakage - utility medium ERO Erratic output FTS Failure to start on demand HIO High output INL Internal leakage LOO Low output NOI Noise OHE Overheating OTH Other PDE Parameter deviation PLU Plugged/ choked SER Minor in-service problems STD Structural deficiency UNK Unknown

Suggest a change

Opens a pre-filled GitHub issue on the COPI repo — nothing is sent until you submit it there.