Core Ontology for Petroleum Installations · INF-UFRGS-Ontologies · CNPq INF-UFRGS-ENERGIA inf.ufrgs.br/ontologies/copi dee69df

emergency shut down valve

CFIHOS TagClass

ID: CFIHOS-30000642

Faça login para ver esta definição.

Hierarchy

Broader / Parent

Properties / Attributes (19)
Name Data Type Unit / Valid values Required Definition
communication protocol Text — Optional The digital communication system (if any), such as HART, Foundation Fieldbus or Profibus
design specification Text — Optional A specification according to which an item is intended to be designed
explosion protection gas group Text — Optional Specify the gas group classification of the physical object in accordance with IEC/EN 60079-20
explosion protection temperature class Text — Optional Specify the temperature classification of the physical object in accordance with CENELEC EN50014
explosion protection zone Text — Optional Specify the hazardous zone in which the functional or physical object is expected to operate.
explosion rated item Boolean — Optional An indicator that an equipment has been classified as safe for use in hazardous areas
failure action Text — Optional The position to which the valve closure member moves when the actuating energy source fails
fire safe Boolean — Optional The standard and classification of the fire rated equipment including valves, firewalls, doors, windows
fluid name Text — Optional The name of the product in liquid or gas phase.
input signal range Text — Optional Signal range (e.g. 4 mA - 20 mA, or 3 - 15 psig) applied to a device, instrument, or system
input signal type Text — Optional Type of instrument signal applied to a device, instrument, or system
nominal diameter Number millimetre Optional A diameter which is an expected (theoretical/as designed) diameter.
normal operating pressure Number bar gauge Optional A pressure at which a functional or physical object is expected to operate normally.
normal operating temperature Number degree celsius Optional A temperature at which a functional or physical object is expected to operate normally.
output signal range Text — Optional Signal range (e.g. 4 mA - 20 mA, or 3 - 15psig) delivered by a device, instrument, or system
output signal type Text — Optional Type of instrument signal delivered by a device, instrument, or system
piping class Text — Optional A specification defined by specified circumstances in which piping components may be applied.
safety integrity level Text — Optional A relative level of risk-reduction provided by a safety function, or to specify a target level of risk reduction
signal type Text — Optional Specify the type of technology used to transmit a signal. For example electric, pneumatic, smart electric etc