Core Ontology for Petroleum Installations · INF-UFRGS-Ontologies · CNPq INF-UFRGS-ENERGIA inf.ufrgs.br/ontologies/copi dee69df

wet transformer

CFIHOS TagAndEquipmentClass

ID: CFIHOS-30000877

Faça login para ver esta definição.

Hierarchy

Broader / Parent

Properties / Attributes (27)
Name Data Type Unit / Valid values Required Definition
explosion protection gas group Text — Optional Specify the gas group classification of the physical object in accordance with IEC/EN 60079-20
explosion protection temperature class Text — Optional Specify the temperature classification of the physical object in accordance with CENELEC EN50014
explosion protection zone Text — Optional Specify the hazardous zone in which the functional or physical object is expected to operate.
explosion rated item Boolean — Optional An indicator that an equipment has been classified as safe for use in hazardous areas
rated primary winding voltage Number volt Optional A rated voltage that is the voltage between lines at the terminals of the primary winding on a transformer at rated output
rated secondary winding voltage Number volt Optional A rated voltage that is the voltage between lines at the terminals of the secondary winding on a transformer at rated output
thermal insulation class Text — Optional The class of electrical insulation used by a physical object.
ATEX category Text — Optional Specify in which category the physical object is divided in accordance with the directive 94/9/EC.
ATEX explosive atmosphere Text — Optional Specify in which explosive atmosphere the physical object is divided in accordance with the directive 94/9/EC.
ATEX group Text — Optional Specify in which group the physical object is divided in accordance with the directive 94/9/EC.
explosion protection concept Text — Optional Specify the identification of electrical equipment's explosion protection and type of ignition protection in accordance with IEC/EN 60079-0.
explosion protection examination certificate number Text — Optional The examination certificate number for the physical object issued by a notified body.
explosion protection material group Text — Optional Specify for purposes of testing, approval, and area classification, various air mixtures (not oxygen-enriched) grouped in accordance with 500.6(A) and (B).
explosion protection notified body Text — Optional The name of the nationally accredited approval body that has issued the examination certificate for the physical object.
impedance voltage Number volt Optional A voltage which is the resultant of reactive and resistance component
ingress protection Text — Optional Specify the degree of ingress protection for the physical object in accordance with IEC/EN 50629 or NEMA, UL and CSA type rating.
load loss Number kilowatt Optional The absorbed active power at rated frequency and reference temperature associated with a pair of windings when rated current is flowing through the line terminals of one of the windings and the terminals of the other windings are short-circuited
no-load loss Number kilowatt Optional The active power absorbed when rated voltage at rated frequency is applied to the terminals of one of the windings, the other windings being open-circuit
number of electrical phases Number COUNT Optional The number of phases in an electrical distribution system.
rated frequency Number hertz Optional An electrical frequency of a machine at rated output
rated output apparent power Number kilovolt-ampere Optional Is an unusable theoretical power which occurs due to capacitive or inductive components. S=UI.
rated output power Number kilowatt Optional A power that is the power a motor has been designed to deliver under specified conditions.
rated power factor (lagging) Number RATIO Optional Dimensionless number between 0 and 1. Cos F = P/S. Where P = upper limit power consumption and S = apparent Power.
rated primary current Number ECURR Optional The current on the primary side in a transformer
rated secondary current Number ECURR Optional The current on the secondary side in a transformer
reactance Number ohm Optional The imaginary part of impedance. Reactance are characterised by the storage of energy rather than by its dissipation, as in resistance.
total weight Number kilogram Optional A weight that is a sum of the weights of identified parts of an assembly.