Core Ontology for Petroleum Installations · INF-UFRGS-Ontologies · CNPq INF-UFRGS-ENERGIA inf.ufrgs.br/ontologies/copi dee69df

choke control valve

CFIHOS TagAndEquipmentClass

ID: CFIHOS-30000811

Faça login para ver esta definição.

Synonyms / Alternative Labels
  • actuated choke valve
Hierarchy

Broader / Parent

Properties / Attributes (40)
Name Data Type Unit / Valid values Required Definition
actuation service Text — Optional Indicates whether the valve will be actuated for on-off or modulating service
communication protocol Text — Optional The digital communication system (if any), such as HART, Foundation Fieldbus or Profibus
design specification Text — Optional A specification according to which an item is intended to be designed
explosion protection gas group Text — Optional Specify the gas group classification of the physical object in accordance with IEC/EN 60079-20
explosion protection temperature class Text — Optional Specify the temperature classification of the physical object in accordance with CENELEC EN50014
explosion protection zone Text — Optional Specify the hazardous zone in which the functional or physical object is expected to operate.
explosion rated item Boolean — Optional An indicator that an equipment has been classified as safe for use in hazardous areas
failure action Text — Optional The position to which the valve closure member moves when the actuating energy source fails
fire safe Boolean — Optional The standard and classification of the fire rated equipment including valves, firewalls, doors, windows
fluid name Text — Optional The name of the product in liquid or gas phase.
full opening valve Boolean — Optional Valve with an unobstructed opening, not smaller than the internal bore of the end connections.
input signal range Text — Optional Signal range (e.g. 4 mA - 20 mA, or 3 - 15 psig) applied to a device, instrument, or system
input signal type Text — Optional Type of instrument signal applied to a device, instrument, or system
nominal diameter Number millimetre Optional A diameter which is an expected (theoretical/as designed) diameter.
normal operating pressure Number bar gauge Optional A pressure at which a functional or physical object is expected to operate normally.
normal operating temperature Number degree celsius Optional A temperature at which a functional or physical object is expected to operate normally.
output signal range Text — Optional Signal range (e.g. 4 mA - 20 mA, or 3 - 15psig) delivered by a device, instrument, or system
output signal type Text — Optional Type of instrument signal delivered by a device, instrument, or system
piping class Text — Optional A specification defined by specified circumstances in which piping components may be applied.
safety integrity level Text — Optional A relative level of risk-reduction provided by a safety function, or to specify a target level of risk reduction
ATEX category Text — Optional Specify in which category the physical object is divided in accordance with the directive 94/9/EC.
ATEX explosive atmosphere Text — Optional Specify in which explosive atmosphere the physical object is divided in accordance with the directive 94/9/EC.
ATEX group Text — Optional Specify in which group the physical object is divided in accordance with the directive 94/9/EC.
body material Text — Optional Is a possessed aspect being a role of the substance of an artefact when used to construct the artefact from. Therefore the substance should be in a solid state at the conditions at which the artefact exists.
explosion protection concept Text — Optional Specify the identification of electrical equipment's explosion protection and type of ignition protection in accordance with IEC/EN 60079-0.
explosion protection examination certificate number Text — Optional The examination certificate number for the physical object issued by a notified body.
explosion protection material group Text — Optional Specify for purposes of testing, approval, and area classification, various air mixtures (not oxygen-enriched) grouped in accordance with 500.6(A) and (B).
explosion protection notified body Text — Optional The name of the nationally accredited approval body that has issued the examination certificate for the physical object.
ingress protection Text — Optional Specify the degree of ingress protection for the physical object in accordance with IEC/EN 50629 or NEMA, UL and CSA type rating.
inlet connection type Text — Optional Type of inlet connection, e.g. socket welded, threaded, butt-welded or flanged
outlet connection type Text — Optional Type of outlet connection, e.g. socket welded, threaded, butt-welded or flanged
pressure rating Text — Optional Classes of standard pressure ratings, i.e. the maximum allowable non shock working gage pressure at a given temperature and a specific material
seat design type Text — Optional Type of seat design
seat leakage class Text — Optional Is the quantity of fluid passing through a valve when the valve is in its fully closed position at a specified process design pressure differential and temperature.
stem sealing type Text — Optional A shaft seal that is a sealing element intended to prevent leakage of fluids/gas between a valve stem and the surrounding body/bonnet.
temperature rating Text — Optional Classes of standard temperature ratings, i.e. the range of temperatures allowable for a specific material.
trim type Text — Optional The internal components of a valve that modulate the flow of the controlled fluid
upper limit allowable pressure Number PRESS Optional The pressure which is the highest allowed.
upper limit operating mass flow rate Number kilogram per hour Optional The mass flow rate which is the highest mass flow rate at which a functional or physical object is expected to operate.
valve operator type Text — Optional The method by which the valve is operated, e.g. gear, actuated, lever, hand wheel, ROV operated etc

Suggest a change

Opens a pre-filled GitHub issue on the COPI repo — nothing is sent until you submit it there.