Core Ontology for Petroleum Installations · INF-UFRGS-Ontologies · CNPq INF-UFRGS-ENERGIA inf.ufrgs.br/ontologies/copi dee69df

self operating valve

CFIHOS TagAndEquipmentClass

ID: CFIHOS-30000682

Faça login para ver esta definição.

Synonyms / Alternative Labels
  • self actuating valve
  • self acting valve
  • regulator
  • self regulating valve
Hierarchy

Broader / Parent

Narrower / Children

Properties / Attributes (14)
Name Data Type Unit / Valid values Required Definition
design specification Text — Optional A specification according to which an item is intended to be designed
explosion protection gas group Text — Optional Specify the gas group classification of the physical object in accordance with IEC/EN 60079-20
explosion protection temperature class Text — Optional Specify the temperature classification of the physical object in accordance with CENELEC EN50014
explosion protection zone Text — Optional Specify the hazardous zone in which the functional or physical object is expected to operate.
explosion rated item Boolean — Optional An indicator that an equipment has been classified as safe for use in hazardous areas
failure action Text — Optional The position to which the valve closure member moves when the actuating energy source fails
fluid name Text — Optional The name of the product in liquid or gas phase.
full opening valve Boolean — Optional Valve with an unobstructed opening, not smaller than the internal bore of the end connections.
nominal diameter Number millimetre Optional A diameter which is an expected (theoretical/as designed) diameter.
normal operating pressure Number bar gauge Optional A pressure at which a functional or physical object is expected to operate normally.
normal operating temperature Number degree celsius Optional A temperature at which a functional or physical object is expected to operate normally.
piping class Text — Optional A specification defined by specified circumstances in which piping components may be applied.
safety integrity level Text — Optional A relative level of risk-reduction provided by a safety function, or to specify a target level of risk reduction
ATEX category Text — Optional Specify in which category the physical object is divided in accordance with the directive 94/9/EC.

Suggest a change

Opens a pre-filled GitHub issue on the COPI repo — nothing is sent until you submit it there.