Core Ontology for Petroleum Installations · INF-UFRGS-Ontologies · CNPq INF-UFRGS-ENERGIA inf.ufrgs.br/ontologies/copi dee69df

solenoid valve

CFIHOS TagAndEquipmentClass

ID: CFIHOS-30000681

Faça login para ver esta definição.

Synonyms / Alternative Labels
  • solenoid operated valve
Hierarchy

Broader / Parent

Properties / Attributes (35)
Name Data Type Unit / Valid values Required Definition
communication protocol Text — Optional The digital communication system (if any), such as HART, Foundation Fieldbus or Profibus
design specification Text — Optional A specification according to which an item is intended to be designed
explosion protection gas group Text — Optional Specify the gas group classification of the physical object in accordance with IEC/EN 60079-20
explosion protection temperature class Text — Optional Specify the temperature classification of the physical object in accordance with CENELEC EN50014
explosion protection zone Text — Optional Specify the hazardous zone in which the functional or physical object is expected to operate.
explosion rated item Boolean — Optional An indicator that an equipment has been classified as safe for use in hazardous areas
failure action Text — Optional The position to which the valve closure member moves when the actuating energy source fails
fluid name Text — Optional The name of the product in liquid or gas phase.
input signal range Text — Optional Signal range (e.g. 4 mA - 20 mA, or 3 - 15 psig) applied to a device, instrument, or system
input signal type Text — Optional Type of instrument signal applied to a device, instrument, or system
nominal diameter Number millimetre Optional A diameter which is an expected (theoretical/as designed) diameter.
normal operating pressure Number bar gauge Optional A pressure at which a functional or physical object is expected to operate normally.
normal operating temperature Number degree celsius Optional A temperature at which a functional or physical object is expected to operate normally.
output signal range Text — Optional Signal range (e.g. 4 mA - 20 mA, or 3 - 15psig) delivered by a device, instrument, or system
output signal type Text — Optional Type of instrument signal delivered by a device, instrument, or system
safety integrity level Text — Optional A relative level of risk-reduction provided by a safety function, or to specify a target level of risk reduction
set point Number — Optional The level at which an instrument is set to trigger an action - e.g. PSVs, bursting discs, regulators, etc.
set point high Number — Optional The highest level at which an instrument is set to trigger an action - e.g. PSVs, bursting discs, regulators, etc.
set point low Number — Optional The lowest level at which an instrument is set to trigger an action - e.g. PSVs, bursting discs, regulators, etc.
ATEX category Text — Optional Specify in which category the physical object is divided in accordance with the directive 94/9/EC.
ATEX explosive atmosphere Text — Optional Specify in which explosive atmosphere the physical object is divided in accordance with the directive 94/9/EC.
ATEX group Text — Optional Specify in which group the physical object is divided in accordance with the directive 94/9/EC.
body material Text — Optional Is a possessed aspect being a role of the substance of an artefact when used to construct the artefact from. Therefore the substance should be in a solid state at the conditions at which the artefact exists.
explosion protection concept Text — Optional Specify the identification of electrical equipment's explosion protection and type of ignition protection in accordance with IEC/EN 60079-0.
explosion protection examination certificate number Text — Optional The examination certificate number for the physical object issued by a notified body.
explosion protection material group Text — Optional Specify for purposes of testing, approval, and area classification, various air mixtures (not oxygen-enriched) grouped in accordance with 500.6(A) and (B).
explosion protection notified body Text — Optional The name of the nationally accredited approval body that has issued the examination certificate for the physical object.
ingress protection Text — Optional Specify the degree of ingress protection for the physical object in accordance with IEC/EN 50629 or NEMA, UL and CSA type rating.
inlet connection type Text — Optional Type of inlet connection, e.g. socket welded, threaded, butt-welded or flanged
outlet connection type Text — Optional Type of outlet connection, e.g. socket welded, threaded, butt-welded or flanged
pressure rating Text — Optional Classes of standard pressure ratings, i.e. the maximum allowable non shock working gage pressure at a given temperature and a specific material
seat design type Text — Optional Type of seat design
seat leakage class Text — Optional Is the quantity of fluid passing through a valve when the valve is in its fully closed position at a specified process design pressure differential and temperature.
temperature rating Text — Optional Classes of standard temperature ratings, i.e. the range of temperatures allowable for a specific material.
valve operator type Text — Optional The method by which the valve is operated, e.g. gear, actuated, lever, hand wheel, ROV operated etc

Suggest a change