Core Ontology for Petroleum Installations · INF-UFRGS-Ontologies · CNPq INF-UFRGS-ENERGIA inf.ufrgs.br/ontologies/copi dee69df

loading arm

CFIHOS TagAndEquipmentClass

ID: CFIHOS-30000602

Faça login para ver esta definição.

Hierarchy

Broader / Parent

Properties / Attributes (21)
Name Data Type Unit / Valid values Required Definition
explosion protection gas group Text — Optional Specify the gas group classification of the physical object in accordance with IEC/EN 60079-20
explosion protection temperature class Text — Optional Specify the temperature classification of the physical object in accordance with CENELEC EN50014
explosion protection zone Text — Optional Specify the hazardous zone in which the functional or physical object is expected to operate.
explosion rated item Boolean — Optional An indicator that an equipment has been classified as safe for use in hazardous areas
fluid name Text — Optional The name of the product in liquid or gas phase.
lower limit design temperature Number degree celsius Optional The lowest temperature at which a functional or physical object is designed.
lower limit operating temperature Number degree celsius Optional A temperature that is the lowest temperature at which a functional or physical object is expected to operate.
normal operating pressure Number bar gauge Optional A pressure at which a functional or physical object is expected to operate normally.
upper limit design temperature Number degree celsius Optional The highest temperature at which a functional or physical object is designed.
upper limit operating temperature Number degree celsius Optional A temperature that is the highest temperature at which a functional or physical object is expected to operate.
ATEX category Text — Optional Specify in which category the physical object is divided in accordance with the directive 94/9/EC.
ATEX explosive atmosphere Text — Optional Specify in which explosive atmosphere the physical object is divided in accordance with the directive 94/9/EC.
ATEX group Text — Optional Specify in which group the physical object is divided in accordance with the directive 94/9/EC.
diameter Number millimetre Optional Intercept made by the circumference on a straight line through the centre of a circle.
explosion protection concept Text — Optional Specify the identification of electrical equipment's explosion protection and type of ignition protection in accordance with IEC/EN 60079-0.
explosion protection examination certificate number Text — Optional The examination certificate number for the physical object issued by a notified body.
explosion protection material group Text — Optional Specify for purposes of testing, approval, and area classification, various air mixtures (not oxygen-enriched) grouped in accordance with 500.6(A) and (B).
explosion protection notified body Text — Optional The name of the nationally accredited approval body that has issued the examination certificate for the physical object.
ingress protection Text — Optional Specify the degree of ingress protection for the physical object in accordance with IEC/EN 50629 or NEMA, UL and CSA type rating.
legal registration number Text — Optional Registration for legal reasons.
nominal diameter Number millimetre Optional A diameter which is an expected (theoretical/as designed) diameter.

Suggest a change

Opens a pre-filled GitHub issue on the COPI repo — nothing is sent until you submit it there.