compressor
CFIHOS
TagAndEquipmentClass
ID: CFIHOS-30000524
Faça login para ver esta definição.
Hierarchy
Properties / Attributes (30)
| Name | Data Type | Unit / Valid values | Required | Definition |
|---|---|---|---|---|
| compressibility factor Z at inlet | Number |
VPROPO | Optional | The compressibility (Z) factor for the process medium at inlet conditions |
| design specification | Text |
— | Optional | A specification according to which an item is intended to be designed |
| direction of rotation | Text |
— | Optional | Specify the direction of rotation of the functional or physical object. |
| explosion protection gas group | Text |
— | Optional | Specify the gas group classification of the physical object in accordance with IEC/EN 60079-20 |
| explosion protection temperature class | Text |
— | Optional | Specify the temperature classification of the physical object in accordance with CENELEC EN50014 |
| explosion protection zone | Text |
— | Optional | Specify the hazardous zone in which the functional or physical object is expected to operate. |
| explosion rated item | Boolean |
— | Optional | An indicator that an equipment has been classified as safe for use in hazardous areas |
| fluid name | Text |
— | Optional | The name of the product in liquid or gas phase. |
| lower limit design outlet temperature | Number |
TEMP | Optional | The temperature which is the lowest temperature a functional or physical object is designed at its outlet connection |
| lower limit operating suction pressure | Number |
bar absolute | Optional | The suction pressure which is the lowest pressure at which a functional or physical object is expected to operate. |
| lower limit operating temperature | Number |
degree celsius | Optional | A temperature that is the lowest temperature at which a functional or physical object is expected to operate. |
| lower limit operating volume flow rate | Number |
cubic metre per hour | Optional | A volume flow rate that is the lowest volume flow rate at which a functional or physical object is expected to operate. |
| molecular weight | Number |
MOLWT | Optional | The sum of all the atomic weights of the constituent atoms of a substance. |
| normal operating dynamic viscosity | Number |
VISDYN | Optional | The dynamic viscosity at which a functional or physical object is expected to operate normally. |
| normal operating inlet pressure | Number |
bar absolute | Optional | An inlet pressure at which a functional or physical object is expected to operate normally. |
| normal operating inlet temperature | Number |
degree celsius | Optional | The temperature at which a functional or physical object is expected to operate normally at its inlet connection. |
| normal operating mass flow rate | Number |
kilogram per hour | Optional | The mass flow rate at which a functional or physical object is expected to operate normally. |
| normal operating outlet pressure | Number |
bar absolute | Optional | The pressure at which a functional or physical object is expected to operate normally at its outlet connection. |
| normal operating volume flow rate (at normal operating pressure and normal operating temperature) | Number |
cubic metre per hour | Optional | The volume flow rate at which a functional or physical object is expected to operate normally. The volume flow rate is calculated at normal operating pressure and normal operating temperature. |
| operation continuous intermittent | Text |
— | Optional | Specifies if the equipment is working continuously or in an intermittent way. |
| specific heat ratio Cp/Cv at inlet | Number |
RATIO | Optional | The specific heat ratio for the process medium at inlet conditions. |
| test medium | Text |
— | Optional | The medium used for testing purpose. |
| test pressure | Number |
bar gauge | Optional | A pressure to which an object should be subjected to test for leakage and structural integrity. |
| thermal insulation class | Text |
— | Optional | The class of electrical insulation used by a physical object. |
| upper limit allowable speed | Number |
revolution per minute | Optional | The speed which is the highest allowed. |
| upper limit design outlet temperature | Number |
TEMP | Optional | The temperature which is the highest temperature a functional or physical object is designed at its outlet connection |
| upper limit design volume flow rate | Number |
VOLFLO | Optional | A volume flow rate that is the highest volume flow rate at which a functional or physical object is designed to operate. |
| upper limit operating inlet pressure | Number |
bar absolute | Optional | The pressure which is the highest pressure at which a functional or physical object is expected to operate at its inlet connection. |
| upper limit operating outlet pressure | Number |
PRESS | Optional | The pressure which is the highest pressure at which a functional or physical object is expected to operate at its outlet connection. |
| upper limit operating temperature | Number |
degree celsius | Optional | A temperature that is the highest temperature at which a functional or physical object is expected to operate. |