pipeline
CFIHOS
TagAndEquipmentClass
ID: CFIHOS-30000500
Faça login para ver esta definição.
Hierarchy
Broader / Parent
Properties / Attributes (23)
| Name | Data Type | Unit / Valid values | Required | Definition |
|---|---|---|---|---|
| buried | Boolean |
— | Optional | Is the functional item buried, yes/no? |
| design specification | Text |
— | Optional | A specification according to which an item is intended to be designed |
| fluid name | Text |
— | Optional | The name of the product in liquid or gas phase. |
| lower limit design temperature | Number |
degree celsius | Optional | The lowest temperature at which a functional or physical object is designed. |
| lower limit operating temperature | Number |
degree celsius | Optional | A temperature that is the lowest temperature at which a functional or physical object is expected to operate. |
| nominal diameter | Number |
millimetre | Optional | A diameter which is an expected (theoretical/as designed) diameter. |
| nominal wall thickness | Number |
millimetre | Optional | Specify the nominal wall thickness of the equipment at the upstream boundary of the section. |
| normal operating mass flow rate | Number |
kilogram per hour | Optional | The mass flow rate at which a functional or physical object is expected to operate normally. |
| normal operating pressure | Number |
bar gauge | Optional | A pressure at which a functional or physical object is expected to operate normally. |
| normal operating temperature | Number |
degree celsius | Optional | A temperature at which a functional or physical object is expected to operate normally. |
| pipeline material and grade | Text |
— | Optional | Specify the type and grade of material that the pipeline is constructed from. |
| upper limit design pressure | Number |
bar gauge | Optional | The highest pressure at which a functional or physical object is designed for. |
| upper limit design temperature | Number |
degree celsius | Optional | The highest temperature at which a functional or physical object is designed. |
| upper limit operating pressure | Number |
bar gauge | Optional | A pressure which is the highest pressure at which a functional or physical object is expected to operate. |
| upper limit operating temperature | Number |
degree celsius | Optional | A temperature that is the highest temperature at which a functional or physical object is expected to operate. |
| weight coating density | Number |
kilogram per cubic metre | Optional | The density of the weight coating material. |
| weight coating thickness | Number |
millimetre | Optional | The total weight coating system thickness. |
| corrosion allowance | Number |
millimetre | Optional | A thickness that is the upper limit of allowed corrosion of a metal structure. |
| hydrostatic test pressure | Number |
bar gauge | Optional | A test pressure applicable when using water to establish the test pressure. |
| lower limit allowable temperature | Number |
TEMP | Optional | The temperature which is the lowest allowed. |
| post weld heat treatment | Boolean |
— | Optional | Is a heat treatment after welding. Intended to ensure that the atomic structure of a weld and heat-affected zone is restored to an optimum corrosion-resistant structure. |
| upper limit allowable pressure | Number |
PRESS | Optional | The pressure which is the highest allowed. |
| upper limit allowable temperature | Number |
TEMP | Optional | The temperature which is the highest allowed. |