pipe
CFIHOS
TagAndEquipmentClass
ID: CFIHOS-30000496
Faça login para ver esta definição.
Synonyms / Alternative Labels
- line
Hierarchy
Broader / Parent
Properties / Attributes (34)
| Name | Data Type | Unit / Valid values | Required | Definition |
|---|---|---|---|---|
| corrosion allowance | Number |
millimetre | Optional | A thickness that is the upper limit of allowed corrosion of a metal structure. |
| design specification | Text |
— | Optional | A specification according to which an item is intended to be designed |
| external coating specification | Text |
— | Optional | Is a material specification for a coating on the outside of the equipment or component |
| fluid name | Text |
— | Optional | The name of the product in liquid or gas phase. |
| insulation code | Text |
— | Optional | Specify insulation code, handbook or industry practice. |
| insulation thickness | Number |
millimetre | Optional | A thickness of an insulation layer. |
| insulation type | Text |
— | Optional | The type of insulation of a functional or physical object. |
| lower limit design pressure | Number |
PRESS | Optional | The lowest pressure at which a functional or physical object is designed. |
| lower limit design temperature | Number |
degree celsius | Optional | The lowest temperature at which a functional or physical object is designed. |
| lower limit operating heat tracing temperature | Number |
degree celsius | Optional | The temperature which is the lowest heat tracing temperature at which a functional or physical object is expected to operate. |
| lower limit operating pressure | Number |
PRESS | Optional | A pressure which is the lowest pressure at which a functional or physical object is expected to operate. |
| lower limit operating temperature | Number |
degree celsius | Optional | A temperature that is the lowest temperature at which a functional or physical object is expected to operate. |
| material specification | Text |
— | Optional | Is a specification which describes the applicable materials for one or more items. |
| nominal diameter | Number |
millimetre | Optional | A diameter which is an expected (theoretical/as designed) diameter. |
| nominal wall thickness | Number |
millimetre | Optional | Specify the nominal wall thickness of the equipment at the upstream boundary of the section. |
| non destructive testing methods | Text |
— | Optional | Specify the non destructive group of methods of checking the structural quality of the functional or physical object. |
| normal operating mass flow rate | Number |
kilogram per hour | Optional | The mass flow rate at which a functional or physical object is expected to operate normally. |
| normal operating pressure | Number |
bar gauge | Optional | A pressure at which a functional or physical object is expected to operate normally. |
| normal operating temperature | Number |
degree celsius | Optional | A temperature at which a functional or physical object is expected to operate normally. |
| normal operating volume flow rate | Number |
VOLFLO | Optional | The volume flow rate at which a functional or physical object is expected to operate normally. |
| paint code | Text |
— | Optional | The code of practice and the painting system within that practice with which the painting of a functional or physical object complies. |
| piping class | Text |
— | Optional | A specification defined by specified circumstances in which piping components may be applied. |
| service code | Text |
— | Optional | A code that indicates a type of product for that an item is intended to be used. |
| upper limit design pressure | Number |
bar gauge | Optional | The highest pressure at which a functional or physical object is designed for. |
| upper limit design temperature | Number |
degree celsius | Optional | The highest temperature at which a functional or physical object is designed. |
| upper limit operating pressure | Number |
bar gauge | Optional | A pressure which is the highest pressure at which a functional or physical object is expected to operate. |
| upper limit operating temperature | Number |
degree celsius | Optional | A temperature that is the highest temperature at which a functional or physical object is expected to operate. |
| hydrostatic test pressure | Number |
bar gauge | Optional | A test pressure applicable when using water to establish the test pressure. |
| lower limit allowable temperature | Number |
TEMP | Optional | The temperature which is the lowest allowed. |
| material | Text |
— | Optional | Is a possessed aspect being a role of the substance of an artefact when used to construct the artefact from. Therefore the substance should be in a solid state at the conditions at which the artefact exists. |
| post weld heat treatment | Boolean |
— | Optional | Is a heat treatment after welding. Intended to ensure that the atomic structure of a weld and heat-affected zone is restored to an optimum corrosion-resistant structure. |
| test medium | Text |
— | Optional | The medium used for testing purpose. |
| upper limit allowable pressure | Number |
PRESS | Optional | The pressure which is the highest allowed. |
| upper limit allowable temperature | Number |
TEMP | Optional | The temperature which is the highest allowed. |