christmas tree
CFIHOS
TagAndEquipmentClass
ID: CFIHOS-30000494
Faça login para ver esta definição.
Hierarchy
Broader / Parent
Properties / Attributes (134)
| Name | Data Type | Unit / Valid values | Required | Definition |
|---|---|---|---|---|
| access port(s) between crown plugs (on HXT) | Text |
— | Optional | Specify the porting into the area between the crown plugs for HXT. |
| annulus access valve | Text |
— | Optional | The annulus access valve annulus access valve (AAV)) type. |
| annulus configuration | Text |
— | Optional | The configuration of the annulus to define the annulus crossover intersection location, valves and sensor locations. |
| annulus gas lift service | Boolean |
— | Optional | The gas lift function requirement. |
| annulus material trim | Text |
— | Optional | The material trim requirements for the annulus. |
| annulus vent or wing valve size | Text |
— | Optional | The nominal size of annulus vent valve (for Configuration #1) or annulus wing valve (for Configuration #2). |
| annulus vent valve | Text |
— | Optional | The annulus vent valve (AVV) type. |
| chemical injection between annulus wing and master valve | Text |
— | Optional | The chemical injection line between annulus wing and master valve (AWV/AMV) isolation requirement type. |
| chemical injection between PMV and PWV - Line #1 | Text |
— | Optional | Select the chemical injection line between PMV and PWV - Line #1 isolation requirement type. |
| conformity assessment system level | Text |
— | Optional | The Conformity Assessment System (CAS) class letter in accordance with IOGP specification and obligatory requirements. |
| connection load capacity | Text |
pound-force | Optional | The connection load capacity of the downhole tubing. |
| cool down 'no touch time' | Number |
minute | Optional | The required cool down 'no touch time'. |
| crossover piping production bore intersection location | Text |
— | Optional | The location for the crossover flow loop to intersect the production (injection) bore. |
| design water depth | Number |
metre | Optional | Specify the design water depth |
| downhole chemical injection (3/8 in. tubing) - Line #4 | Text |
— | Optional | The isolation requirement type if the line is used or 'blanked' if the line is unused. |
| downhole chemical injection line isolation valve material trim option | Text |
— | Optional | The material trim class for the downhole chemical injection line isolation valve. |
| downhole chemical injection line valve and porting upgraded to HH trim option | Text |
— | Optional | Specify if the block porting and the isolation valve for one of the downhole lines is required to be upgraded to HH trim. |
| downhole electric and fiber optic line selection | Text |
— | Optional | The downhole electric and fiber optic line selection. |
| drift diameter | Number |
millimetre | Optional | The production tubing drift diameter. |
| drift diameter of landing string | Number |
millimetre | Optional | The minimum drift diameter of the landing string to allow specification of appropriately-sized HXT crown plugs or VXT TH plugs. |
| dry weight | Number |
kilogram | Optional | A weight of an object excluding any operating or process fluids. |
| erosion condition monitoring | Boolean |
— | Optional | Specify if flowline erosion condition monitoring is required. |
| flowing wellhead temperature | Number |
degree celsius | Optional | The flowing wellhead temperature. |
| flowline connection location | Text |
— | Optional | The flowline connection location. |
| flowline connection type | Text |
— | Optional | The flowline connection type. |
| flowline leak detection | Boolean |
— | Optional | Specify if flowline leak detection is required. |
| flowline sand detector | Boolean |
— | Optional | Specify if flowline sand detection is required. |
| gas lift choke | Boolean |
— | Optional | Specify if a gas lift choke is required. |
| gas lift choke configuration and retrieval method | Text |
— | Optional | The gas lift choke/insert configuration and retrieval method. |
| gas lift choke operation | Text |
— | Optional | The gas lift choke operation type. |
| gas lift flow meter | Boolean |
— | Optional | Specify if a gas lift flow meter is required. |
| gas lift flow meter retrieval method | Text |
— | Optional | The gas lift flow meter retrieval method. |
| gas lift isolation valve | Text |
— | Optional | Select subsea tree valve and actuator gas lift isolation type options. |
| insulation required | Boolean |
— | Optional | Specify if insulation is required or not. |
| line size of chemical injection Line #1 | Text |
— | Optional | The line size for the chemical injection Line #1. |
| location of additional 1 in tubing chemical injection line | Text |
— | Optional | The location for the single additional 1 in. (25 mm) OD tubing chemical injection line option. |
| material grade | Text |
— | Optional | The material grade of the downhole tubing. |
| metering for chemical injection between PMV and PWV - Line #1 | Boolean |
— | Optional | Specify if metering for chemical injection between PMV and PWV - Line #1 is required. |
| metering for chemical injection between PWV and PCV - Line #2 | Boolean |
— | Optional | Specify if metering for chemical injection between PWV and PCV - Line #2 is required. |
| metering for chemical injection between PWV and PCV - Line #3 | Boolean |
— | Optional | Specify if metering for chemical injection between PWV and PCV - Line #3 is required. |
| metering for chemical injection outboard of PCV - Line #4 | Boolean |
— | Optional | Specify if metering for chemical injection outboard of PCV - Line #4 is required. |
| metering for downhole chemical injection - Line #1 | Boolean |
— | Optional | Specify if metering for downhole chemical injection - Line #1 is required. |
| metering for downhole chemical injection - Line #2 | Boolean |
— | Optional | Specify if metering for downhole chemical injection - Line #2 is required. |
| metering for downhole chemical injection - Line #3 | Boolean |
— | Optional | Specify if metering for downhole chemical injection - Line #3 is required. |
| metering for downhole chemical injection - Line #4 | Boolean |
— | Optional | Specify if metering for downhole chemical injection - Line #4 is required. |
| minimum temperature for cool down 'no touch time' | Number |
TEMP | Optional | The minimum temperature that must be maintained during the specified 'no touch time'. |
| minimum TRL for components, equipment, and assemblies | Text |
— | Optional | The minimum TRL for components, equipment and assemblies. |
| minimum vertical access bore through tree and tubing hanger | Number |
millimetre | Optional | The minimum vertical access bore diameter through the x-mas tree and tubing hanger. |
| monogramming of underwater safety valves | Boolean |
— | Optional | Specify if the USVs are to be monogrammed per API. |
| normal operating pressure | Number |
PRESS | Optional | A pressure at which a functional or physical object is expected to operate normally. |
| number of downhole hydraulic lines | Number |
piece | Optional | The total number of downhole hydraulic lines required (including chemical injection, hydraulic surface-controlled subsurface safety valves (SCSSV) and hydraulic IWC lines in total). |
| number of hydraulic lines for each hydraulic SCSSV | Number |
COUNT | Optional | The number of downhole hydraulic lines required for each hydraulic surface-controlled subsurface safety valves (SCSSV). |
| number of SCSSVs | Number |
piece | Optional | The total number of surface-controlled subsurface safety valves (SCSSV) (hydraulic and electric). |
| outside diameter | Number |
millimetre | Optional | A diameter that is across the outside cross section of a circular object. |
| pig detection | Boolean |
— | Optional | Specify if flowline pig detection is required. |
| pressure-containing tree cap locking method | Text |
— | Optional | The method for locking the pressure-containing tree cap to the tree mandrel. |
| production (injection) choke configuration and retrieval method | Text |
— | Optional | The production (injection) choke mounting and retrieval configuration. |
| production (injection) choke operation | Text |
— | Optional | The choke operation type. |
| production (injection) choke step size/profile | Text |
— | Optional | The choke step size and profile details. |
| production (injection) choke valve flow coefficient of velocity | Text |
— | Optional | The tree-mounted production (injection) choke valve flow coefficient. |
| production (injection) flow meter | Text |
— | Optional | The type of flow meter required on the production (injection) bore. |
| production (injection) flow meter retrieval method | Text |
— | Optional | The production (injection) flow meter retrieval method. |
| production isolation valve type | Text |
— | Optional | The production isolation valve (PIV) type. |
| production valve size | Text |
— | Optional | The nominal size of the production (injection) bore and valves. |
| rated current for electric SCSSV | Number |
ampere | Optional | The electric power requirements of each electric surface-controlled subsurface safety valves (SCSSV) in amps. |
| rated voltage for electric SCSSV | Number |
volt | Optional | The electric power requirements of each electric surface-controlled subsurface safety valves (SCSSV) in volts. |
| seabed hydrates expected | Boolean |
— | Optional | Select whether seabed hydrates are expected. |
| sensor element type for annulus bore between annulus master and wing valve | Text |
— | Optional | The sensor element type for annulus bore between annulus master and wing valve (AMV/AWV). |
| sensor element type for annulus bore inboard of annulus master valve | Text |
— | Optional | The sensor element type for annulus bore inboard of annulus master valve (AMV). |
| sensor element type for annulus bore outboard of annulus wing valve | Text |
— | Optional | The sensor element type for annulus bore outboard of AWV. |
| sensor element type for production bore between PMV and PWV | Text |
— | Optional | The sensor element type for production bore between PMV and PWV. |
| sensor element type for production bore downstream of PCV | Text |
— | Optional | The sensor element type for production bore downstream of PCV. |
| service and assembly product specification level | Text |
— | Optional | The product specification level (PSL) requirement based on the service type. |
| snag load protection | Boolean |
— | Optional | Specify if snag load protection is required. |
| subsea tree temperature class | Text |
— | Optional | The subsea tree API temperature class. |
| through-bore drill-bit size for drift capability (for HXT or THS only) | Text |
— | Optional | The through-bore drill-bit size for drift capability (for HXT or tubing head spool (THS) only). |
| tubing hanger bottom connection details for downhole electric/fiber optic line(s) | Text |
— | Optional | The connection details (connector type and preparation) for downhole electric and fiber optic connections to bottom of tubing hanger. |
| tubing hanger bottom tubing connection for SCSSV line(s) | Text |
— | Optional | The connection details (connector type and preparation) for surface-controlled subsurface safety valves (SCSSV) hydraulic connection(s) to the bottom of the tubing hanger (TH). |
| tubing hanger bottom tubing connection type for downhole hydraulic and chemical injection lines | Text |
— | Optional | The connection details (connector type and prep) for the downhole tubing connections to the bottom of the tubing hanger. |
| tubing hanger orientation | Text |
— | Optional | The method or source of tubing hanger rotational orientation. |
| tubing hanger pup joint / saver sub bore | Number |
millimetre | Optional | The TH pup joint / saver sub bore. |
| tubing hanger pup joint / saver sub connection type | Text |
— | Optional | The TH pup joint / saver sub connection type. |
| tubing hanger pup joint / saver sub length | Number |
millimetre | Optional | The TH pup joint / saver sub length. |
| tubing hanger pup joint / saver sub outer diameter | Number |
millimetre | Optional | The TH pup joint / saver sub outer diameter. |
| type of connection | Text |
— | Optional | The connection type of the downhole tubing. |
| type of subsea tree | Text |
— | Optional | The type of subsea tree. |
| underwater safety valve designations | Text |
— | Optional | The valves to be designated as underwater safety valve (USV). If 'other' is selected, Specify the valve(s) to be designated as USV(s) in the 'Additional notes' column. |
| upper limit design pressure | Number |
bar | Optional | The highest pressure at which a functional or physical object is designed for. |
| upper limit operating pressure | Number |
bar | Optional | A pressure which is the highest pressure at which a functional or physical object is expected to operate. |
| valve isolation chemical injection between PWV and PCV - Line #2 | Text |
— | Optional | The line isolation requirement type between production wing valve (PWV and pressure control valve (PCV). |
| valve isolation chemical injection between PWV and PCV - Line #3 | Text |
— | Optional | The line isolation requirement type between production wing valve (PWV) and pressure control valve (PCV). |
| valve isolation chemical injection outboard of PCV - Line #4 | Text |
— | Optional | The line isolation requirement type (pressure control valve (PCV)). |
| valve isolation downhole chemical injection (3/8 in. tubing) - Line #1 | Text |
— | Optional | The isolation requirement type if the line is used or 'line not present or port blanked' if the line is unused. |
| valve isolation downhole chemical injection (3/8 in. tubing) - Line #2 | Text |
— | Optional | The isolation requirement type if the line is used or 'line not present or blanked' if the line is unused. |
| valve isolation downhole chemical injection (3/8 in. tubing) - Line #3 | Text |
— | Optional | The isolation requirement type if the line is used or 'line not present or port blanked' if the line is unused. |
| valve ROV override type | Text |
— | Optional | The valve ROV override type. |
| VXT – swab valves (PSV and ASV) | Text |
— | Optional | The vertical christmas tree (VXT) swab valves type. Pressure safety valve (PSV) and anti-surge valve (ASV). |
| VXT other tubing plug model | Text |
— | Optional | The VXT tubing plug or other plug model. |
| VXT other tubing plug pressure rating | Number |
bar | Optional | The VXT tubing plug or other plug pressure rating. |
| VXT other tubing plug size | Text |
— | Optional | The VXT tubing plug or other plug size. |
| VXT other tubing plug type | Text |
— | Optional | The VXT tubing plug or other plug type. |
| VXT pressure-containing tree cap configuration | Text |
— | Optional | The production and annulus bores isolation. |
| VXT tree cap pressure-containing seals | Text |
— | Optional | The type of sealing (metal-to-metal or non-metallic) to be used for pressure-containing seals of the VXT tree cap. |
| VXT tubing hanger annulus bore plug model | Text |
— | Optional | The VXT TH annulus bore plug model. |
| VXT tubing hanger annulus bore plug pressure rating | Number |
bar | Optional | The VXT TH annulus bore plug pressure rating. |
| VXT tubing hanger annulus bore plug size | Text |
— | Optional | The VXT TH annulus bore plug size. |
| VXT tubing hanger annulus bore plug type | Text |
— | Optional | The VXT TH annulus bore plug type. |
| VXT tubing hanger external A annulus seals | Text |
— | Optional | The type of sealing (metal-to-metal or non-metallic) to be used for VXT tubing hanger external A annulus seals. |
| VXT tubing hanger production bore plug model | Text |
— | Optional | The VXT TH production bore plug model. |
| VXT tubing hanger production bore plug pressure rating | Number |
bar | Optional | The VXT TH production bore plug pressure rating. |
| VXT tubing hanger production bore plug size | Text |
— | Optional | The VXT TH production bore plug size. |
| VXT tubing hanger production bore plug type | Text |
— | Optional | The VXT TH production bore plug type. |
| wellhead connector hydrate prevention and inhibition | Boolean |
— | Optional | Select whether wellhead connector hydrate prevention and inhibition are required. |
| wellhead connector/mandrel type | Text |
— | Optional | The mandrel and wellhead connector type. |
| wellhead gasket retention mechanism requirement | Text |
— | Optional | The components on which wellhead gasket retention mechanisms are required. |
| wellhead isolation-sleeve sealing location | Text |
— | Optional | The lower seal sealing location of the wellhead isolation-sleeve. |
| asphaltenes | Boolean |
— | Optional | Specify if asphaltenes is present or not. |
| flow rate capability for THAID with less than 1 in² flow-by area | Number |
cubic metre per day | Optional | The flow rate capability for THAID with less than 1 in² flow-by area considering maximum required gas lift, well kill and circulation. |
| HXT lower crown plug model | Text |
— | Optional | The lower crown plug model. |
| HXT lower crown plug pressure rating | Number |
bar | Optional | The lower crown plug pressure rating. |
| HXT lower crown plug size | Text |
— | Optional | The lower crown plug size. |
| HXT lower crown plug type | Text |
— | Optional | The lower crown plug type. |
| HXT upper crown plug model | Text |
— | Optional | The upper crown plug model. |
| HXT upper crown plug pressure rating | Number |
bar | Optional | The upper crown plug pressure rating. |
| HXT upper crown plug size | Text |
— | Optional | The upper crown plug size. |
| HXT upper crown plug type | Text |
— | Optional | The upper crown plug type. |
| hydrate formation | Boolean |
— | Optional | Specify if hydration formation occurred or not. |
| mudline suspension system | Boolean |
— | Optional | Define whether a mudline suspension system exists or not. |
| number of connection | Number |
COUNT | Optional | Number of lines connected to the equipment |
| piggable | Boolean |
— | Optional | Specify if piggable or not. |
| sand production | Boolean |
— | Optional | Specify if sand produced or not. |
| scale formation | Boolean |
— | Optional | Specify if scale formation occurred or not. |
| tubing hanger rotational torque resistance capacity | Text |
— | Optional | The required rotational torque resistance capacity of the tubing hanger. |
| wax formation | Boolean |
— | Optional | Specify if wax formation occurred or not. |