Core Ontology for Petroleum Installations · INF-UFRGS-Ontologies · CNPq INF-UFRGS-ENERGIA inf.ufrgs.br/ontologies/copi dee69df

heating cable

CFIHOS TagAndEquipmentClass

ID: CFIHOS-30000349

Faça login para ver esta definição.

Synonyms / Alternative Labels
  • electric cable
  • heat tracing
Hierarchy

Broader / Parent

Properties / Attributes (21)
Name Data Type Unit / Valid values Required Definition
explosion protection gas group Text — Optional Specify the gas group classification of the physical object in accordance with IEC/EN 60079-20
explosion protection temperature class Text — Optional Specify the temperature classification of the physical object in accordance with CENELEC EN50014
explosion protection zone Text — Optional Specify the hazardous zone in which the functional or physical object is expected to operate.
explosion rated item Boolean — Optional An indicator that an equipment has been classified as safe for use in hazardous areas
length Number millimetre Optional Is a distance measured in the direction of the longest side of an item or in the direction of its main axis.
nominal current Number ampere Optional A current which is the current a functional or physical object has been designed to operate normally.
normal operating power consumption Number POWER Optional A power consumption at normal working conditions.
operating voltage Number VOLTAG Optional The voltage under normal working conditions, at a given instant.
rated current Number ampere Optional The r.m.s. or DC value of the current for which an apparatus has been designed
rated power consumption Number kilowatt Optional A power consumption at rated conditions.
rated voltage Number volt Optional A voltage that is the voltage between lines at the terminals of the machine at rated output
actual length Number metre Optional The actual length of the functional or physical object.
ATEX category Text — Optional Specify in which category the physical object is divided in accordance with the directive 94/9/EC.
ATEX explosive atmosphere Text — Optional Specify in which explosive atmosphere the physical object is divided in accordance with the directive 94/9/EC.
ATEX group Text — Optional Specify in which group the physical object is divided in accordance with the directive 94/9/EC.
cable type Text — Optional The code describing the construction of the cable.
explosion protection concept Text — Optional Specify the identification of electrical equipment's explosion protection and type of ignition protection in accordance with IEC/EN 60079-0.
explosion protection examination certificate number Text — Optional The examination certificate number for the physical object issued by a notified body.
explosion protection material group Text — Optional Specify for purposes of testing, approval, and area classification, various air mixtures (not oxygen-enriched) grouped in accordance with 500.6(A) and (B).
explosion protection notified body Text — Optional The name of the nationally accredited approval body that has issued the examination certificate for the physical object.
ingress protection Text — Optional Specify the degree of ingress protection for the physical object in accordance with IEC/EN 50629 or NEMA, UL and CSA type rating.

Suggest a change

Opens a pre-filled GitHub issue on the COPI repo — nothing is sent until you submit it there.