manifold
CFIHOS
TagAndEquipmentClass
ID: CFIHOS-30000308
Faça login para ver esta definição.
Hierarchy
Broader / Parent
Properties / Attributes (19)
| Name | Data Type | Unit / Valid values | Required | Definition |
|---|---|---|---|---|
| design specification | Text |
— | Optional | A specification according to which an item is intended to be designed |
| explosion protection gas group | Text |
— | Optional | Specify the gas group classification of the physical object in accordance with IEC/EN 60079-20 |
| explosion protection temperature class | Text |
— | Optional | Specify the temperature classification of the physical object in accordance with CENELEC EN50014 |
| explosion protection zone | Text |
— | Optional | Specify the hazardous zone in which the functional or physical object is expected to operate. |
| explosion rated item | Boolean |
— | Optional | An indicator that an equipment has been classified as safe for use in hazardous areas |
| fluid name | Text |
— | Optional | The name of the product in liquid or gas phase. |
| lower limit design temperature | Number |
TEMP | Optional | The lowest temperature at which a functional or physical object is designed. |
| normal operating temperature | Number |
degree celsius | Optional | A temperature at which a functional or physical object is expected to operate normally. |
| normal volume flow rate | Number |
VOLFLO | Optional | A volume flow rate a functional or physical object is designed to deliver under normal conditions. |
| upper limit design pressure | Number |
bar gauge | Optional | The highest pressure at which a functional or physical object is designed for. |
| upper limit design temperature | Number |
degree celsius | Optional | The highest temperature at which a functional or physical object is designed. |
| insulation required | Boolean |
— | Optional | Specify if insulation is required or not. |
| length | Number |
millimetre | Optional | Is a distance measured in the direction of the longest side of an item or in the direction of its main axis. |
| lower limit allowable temperature | Number |
TEMP | Optional | The temperature which is the lowest allowed. |
| material | Text |
— | Optional | Is a possessed aspect being a role of the substance of an artefact when used to construct the artefact from. Therefore the substance should be in a solid state at the conditions at which the artefact exists. |
| nominal pipe diameter | Number |
millimetre | Optional | The nominal diameter (i.e. not the actual diameter, but an approximate diameter as it may appear on a vendor datasheet) of the equipment at the upstream boundary of the section. |
| operating weight | Number |
kilogram | Optional | A weight that is the weight an object is expected to have during operation, i.e. including process fluids etc. |
| upper limit allowable pressure | Number |
PRESS | Optional | The pressure which is the highest allowed. |
| upper limit allowable temperature | Number |
TEMP | Optional | The temperature which is the highest allowed. |