relief valve

CFIHOS TagAndEquipmentClass

ID: CFIHOS-30000295

Faça login para ver esta definição.

Properties / Attributes (22)
Name Data Type Unit / Valid values Required Definition
body material Text — Optional Is a possessed aspect being a role of the substance of an artefact when used to construct the artefact from. Therefore the substance should be in a solid state at the conditions at which the artefact exists.
cold differential test pressure Number bar gauge Optional Is the pressure at which the pressure relief valve is adjusted to open on the bench. It includes corrections for back pressure and/or temperature
constant back pressure Number bar gauge Optional A back pressure that does not change under any conditions of operation.
design specification Text — Optional A specification according to which an item is intended to be designed
fluid name Text — Optional The name of the product in liquid or gas phase.
fluid phase Text — Optional Specify if the fluid is in liquid, gas or both phases.
lower limit design temperature Number degree celsius Optional The lowest temperature at which a functional or physical object is designed.
nominal inlet diameter Number millimetre Optional Is a diameter by which a quantitative diameter is referred to. Typically a standardized value with defined tolerances.
nominal outlet diameter Number millimetre Optional Is a diameter by which a quantitative diameter is referred to. Typically a standardized value with defined tolerances.
normal operating dynamic viscosity Number millipascal second Optional The dynamic viscosity at which a functional or physical object is expected to operate normally.
normal operating mass flow rate Number kilogram per hour Optional The mass flow rate at which a functional or physical object is expected to operate normally.
normal operating pressure Number bar gauge Optional A pressure at which a functional or physical object is expected to operate normally.
normal operating temperature Number degree celsius Optional A temperature at which a functional or physical object is expected to operate normally.
orifice area calculated Number square millimetre Optional An orifice area that is calculated.
relief bellows Boolean — Optional Is a collection of items each of which is a relief bellow.
safety integrity level Text — Optional A relative level of risk-reduction provided by a safety function, or to specify a target level of risk reduction
set pressure Number bar gauge Optional A pressure at which an object is activated.
spring material specification Text — Optional Is a specification which describes the applicable materials for one or more items.
test medium Text — Optional The medium used for testing purpose.
test pressure Number bar gauge Optional A pressure to which an object should be subjected to test for leakage and structural integrity.
upper limit operating temperature Number degree celsius Optional A temperature that is the highest temperature at which a functional or physical object is expected to operate.
variable back pressure Number bar gauge Optional A back pressure that varies due to changes in operation of one or more pressure relief valves connected into a common discharge header.