Core Ontology for Petroleum Installations · INF-UFRGS-Ontologies · CNPq INF-UFRGS-ENERGIA inf.ufrgs.br/ontologies/copi dee69df

agitator

CFIHOS TagAndEquipmentClass

ID: CFIHOS-30000102

Faça login para ver esta definição.

Hierarchy

Broader / Parent

Properties / Attributes (19)
Name Data Type Unit / Valid values Required Definition
design specification Text — Optional A specification according to which an item is intended to be designed
explosion protection gas group Text — Optional Specify the gas group classification of the physical object in accordance with IEC/EN 60079-20
explosion protection temperature class Text — Optional Specify the temperature classification of the physical object in accordance with CENELEC EN50014
explosion protection zone Text — Optional Specify the hazardous zone in which the functional or physical object is expected to operate.
explosion rated item Boolean — Optional An indicator that an equipment has been classified as safe for use in hazardous areas
fluid name Text — Optional The name of the product in liquid or gas phase.
lower limit operating temperature Number degree celsius Optional A temperature that is the lowest temperature at which a functional or physical object is expected to operate.
normal operating liquid dynamic viscosity Number VISDYN Optional The dynamic viscosity of the fluid in liquid phase at which a functional or physical object is expected to operate normally.
operation continuous intermittent Text — Optional Specifies if the equipment is working continuously or in an intermittent way.
upper limit design temperature Number degree celsius Optional The highest temperature at which a functional or physical object is designed.
upper limit design volume flow rate Number VOLFLO Optional A volume flow rate that is the highest volume flow rate at which a functional or physical object is designed to operate.
upper limit operating temperature Number degree celsius Optional A temperature that is the highest temperature at which a functional or physical object is expected to operate.
ATEX category Text — Optional Specify in which category the physical object is divided in accordance with the directive 94/9/EC.
ATEX explosive atmosphere Text — Optional Specify in which explosive atmosphere the physical object is divided in accordance with the directive 94/9/EC.
ATEX group Text — Optional Specify in which group the physical object is divided in accordance with the directive 94/9/EC.
explosion protection concept Text — Optional Specify the identification of electrical equipment's explosion protection and type of ignition protection in accordance with IEC/EN 60079-0.
explosion protection examination certificate number Text — Optional The examination certificate number for the physical object issued by a notified body.
explosion protection material group Text — Optional Specify for purposes of testing, approval, and area classification, various air mixtures (not oxygen-enriched) grouped in accordance with 500.6(A) and (B).
explosion protection notified body Text — Optional The name of the nationally accredited approval body that has issued the examination certificate for the physical object.

Suggest a change

Opens a pre-filled GitHub issue on the COPI repo — nothing is sent until you submit it there.