agitator
CFIHOS
TagAndEquipmentClass
ID: CFIHOS-30000102
Faça login para ver esta definição.
Hierarchy
Broader / Parent
- mixer CFIHOS
Properties / Attributes (19)
| Name | Data Type | Unit / Valid values | Required | Definition |
|---|---|---|---|---|
| design specification | Text |
— | Optional | A specification according to which an item is intended to be designed |
| explosion protection gas group | Text |
— | Optional | Specify the gas group classification of the physical object in accordance with IEC/EN 60079-20 |
| explosion protection temperature class | Text |
— | Optional | Specify the temperature classification of the physical object in accordance with CENELEC EN50014 |
| explosion protection zone | Text |
— | Optional | Specify the hazardous zone in which the functional or physical object is expected to operate. |
| explosion rated item | Boolean |
— | Optional | An indicator that an equipment has been classified as safe for use in hazardous areas |
| fluid name | Text |
— | Optional | The name of the product in liquid or gas phase. |
| lower limit operating temperature | Number |
degree celsius | Optional | A temperature that is the lowest temperature at which a functional or physical object is expected to operate. |
| normal operating liquid dynamic viscosity | Number |
VISDYN | Optional | The dynamic viscosity of the fluid in liquid phase at which a functional or physical object is expected to operate normally. |
| operation continuous intermittent | Text |
— | Optional | Specifies if the equipment is working continuously or in an intermittent way. |
| upper limit design temperature | Number |
degree celsius | Optional | The highest temperature at which a functional or physical object is designed. |
| upper limit design volume flow rate | Number |
VOLFLO | Optional | A volume flow rate that is the highest volume flow rate at which a functional or physical object is designed to operate. |
| upper limit operating temperature | Number |
degree celsius | Optional | A temperature that is the highest temperature at which a functional or physical object is expected to operate. |
| ATEX category | Text |
— | Optional | Specify in which category the physical object is divided in accordance with the directive 94/9/EC. |
| ATEX explosive atmosphere | Text |
— | Optional | Specify in which explosive atmosphere the physical object is divided in accordance with the directive 94/9/EC. |
| ATEX group | Text |
— | Optional | Specify in which group the physical object is divided in accordance with the directive 94/9/EC. |
| explosion protection concept | Text |
— | Optional | Specify the identification of electrical equipment's explosion protection and type of ignition protection in accordance with IEC/EN 60079-0. |
| explosion protection examination certificate number | Text |
— | Optional | The examination certificate number for the physical object issued by a notified body. |
| explosion protection material group | Text |
— | Optional | Specify for purposes of testing, approval, and area classification, various air mixtures (not oxygen-enriched) grouped in accordance with 500.6(A) and (B). |
| explosion protection notified body | Text |
— | Optional | The name of the nationally accredited approval body that has issued the examination certificate for the physical object. |