Core Ontology for Petroleum Installations · INF-UFRGS-Ontologies · CNPq INF-UFRGS-ENERGIA inf.ufrgs.br/ontologies/copi dee69df

flame arrestor

CFIHOS TagAndEquipmentClass

ID: CFIHOS-30000056

Faça login para ver esta definição.

Hierarchy

Broader / Parent

Properties / Attributes (16)
Name Data Type Unit / Valid values Required Definition
explosion protection gas group Text — Optional Specify the gas group classification of the physical object in accordance with IEC/EN 60079-20
explosion protection temperature class Text — Optional Specify the temperature classification of the physical object in accordance with CENELEC EN50014
explosion protection zone Text — Optional Specify the hazardous zone in which the functional or physical object is expected to operate.
explosion rated item Boolean — Optional An indicator that an equipment has been classified as safe for use in hazardous areas
lower limit design pressure Number PRESS Optional The lowest pressure at which a functional or physical object is designed.
lower limit design temperature Number degree celsius Optional The lowest temperature at which a functional or physical object is designed.
lower limit operating pressure Number PRESS Optional A pressure which is the lowest pressure at which a functional or physical object is expected to operate.
lower limit operating temperature Number degree celsius Optional A temperature that is the lowest temperature at which a functional or physical object is expected to operate.
normal operating pressure Number bar gauge Optional A pressure at which a functional or physical object is expected to operate normally.
normal operating temperature Number degree celsius Optional A temperature at which a functional or physical object is expected to operate normally.
upper limit design temperature Number degree celsius Optional The highest temperature at which a functional or physical object is designed.
upper limit operating pressure Number bar gauge Optional A pressure which is the highest pressure at which a functional or physical object is expected to operate.
upper limit operating temperature Number degree celsius Optional A temperature that is the highest temperature at which a functional or physical object is expected to operate.
casing material Text — Optional Is a possessed aspect being a role of the substance of an artefact when used to construct the artefact from. Therefore the substance should be in a solid state at the conditions at which the artefact exists.
Inspection authority Text — Optional Is a agency that is intended to issue or verify adherence to regulations.
insulation required Boolean — Optional Specify if insulation is required or not.

Suggest a change

Opens a pre-filled GitHub issue on the COPI repo — nothing is sent until you submit it there.