Core Ontology for Petroleum Installations · INF-UFRGS-Ontologies · CNPq INF-UFRGS-ENERGIA inf.ufrgs.br/ontologies/copi dee69df

fired heater

CFIHOS TagAndEquipmentClass

ID: CFIHOS-30000053

Faça login para ver esta definição.

Hierarchy

Broader / Parent

Properties / Attributes (32)
Name Data Type Unit / Valid values Required Definition
coil upper limit design pressure Number bar gauge Optional The highest pressure at which a functional or physical object is designed for.
explosion protection gas group Text — Optional Specify the gas group classification of the physical object in accordance with IEC/EN 60079-20
explosion protection temperature class Text — Optional Specify the temperature classification of the physical object in accordance with CENELEC EN50014
explosion protection zone Text — Optional Specify the hazardous zone in which the functional or physical object is expected to operate.
explosion rated item Boolean — Optional An indicator that an equipment has been classified as safe for use in hazardous areas
fluid name Text — Optional The name of the product in liquid or gas phase.
hydrostatic test pressure Number bar gauge Optional A test pressure applicable when using water to establish the test pressure.
normal operating inlet pressure Number bar absolute Optional An inlet pressure at which a functional or physical object is expected to operate normally.
normal operating inlet temperature Number degree celsius Optional The temperature at which a functional or physical object is expected to operate normally at its inlet connection.
normal operating outlet pressure Number bar absolute Optional The pressure at which a functional or physical object is expected to operate normally at its outlet connection.
normal operating outlet temperature Number degree celsius Optional Is a temperature that occurs during operation or under which an object is supposed to operate.
number of passes Number COUNT Optional Is a number of items where each item is a tube pass.
ATEX category Text — Optional Specify in which category the physical object is divided in accordance with the directive 94/9/EC.
ATEX explosive atmosphere Text — Optional Specify in which explosive atmosphere the physical object is divided in accordance with the directive 94/9/EC.
ATEX group Text — Optional Specify in which group the physical object is divided in accordance with the directive 94/9/EC.
explosion protection concept Text — Optional Specify the identification of electrical equipment's explosion protection and type of ignition protection in accordance with IEC/EN 60079-0.
explosion protection examination certificate number Text — Optional The examination certificate number for the physical object issued by a notified body.
explosion protection material group Text — Optional Specify for purposes of testing, approval, and area classification, various air mixtures (not oxygen-enriched) grouped in accordance with 500.6(A) and (B).
explosion protection notified body Text — Optional The name of the nationally accredited approval body that has issued the examination certificate for the physical object.
floor material Text — Optional The material from which the floor is constructed or an additional covering to strengthen or protect the surface of the floor structure.
head lining material Text — Optional Is a material of construction of which a lining is made.
head material Text — Optional Is a possessed aspect being a role of the substance of an artefact when used to construct the artefact from. Therefore the substance should be in a solid state at the conditions at which the artefact exists.
head wall thickness Number millimetre Optional Is a thickness according to a design.
ingress protection Text — Optional Specify the degree of ingress protection for the physical object in accordance with IEC/EN 50629 or NEMA, UL and CSA type rating.
legal registration number Text — Optional Registration for legal reasons.
maximum tube metal temperature Number degree celsius Optional Is a temperature that is the highest at which a significant load can be applied.
post weld heat treatment Boolean — Optional Is a heat treatment after welding. Intended to ensure that the atomic structure of a weld and heat-affected zone is restored to an optimum corrosion-resistant structure.
shell material Text — Optional Is a possessed aspect being a role of the substance of an artefact when used to construct the artefact from. Therefore the substance should be in a solid state at the conditions at which the artefact exists.
tube length Number millimetre Optional A distance that is the length of a tube.
tube material specification Text — Optional Is a specification which describes the applicable materials for one or more items.
tube outside diameter Number millimetre Optional Is an outside diameter of an item that is the prime outside diameter in case the item has more than one outside diameter.
tube wall thickness Number millimetre Optional Is a thickness according to a design.