fired heater
CFIHOS
TagAndEquipmentClass
ID: CFIHOS-30000053
Faça login para ver esta definição.
Hierarchy
Broader / Parent
Properties / Attributes (32)
| Name | Data Type | Unit / Valid values | Required | Definition |
|---|---|---|---|---|
| coil upper limit design pressure | Number |
bar gauge | Optional | The highest pressure at which a functional or physical object is designed for. |
| explosion protection gas group | Text |
— | Optional | Specify the gas group classification of the physical object in accordance with IEC/EN 60079-20 |
| explosion protection temperature class | Text |
— | Optional | Specify the temperature classification of the physical object in accordance with CENELEC EN50014 |
| explosion protection zone | Text |
— | Optional | Specify the hazardous zone in which the functional or physical object is expected to operate. |
| explosion rated item | Boolean |
— | Optional | An indicator that an equipment has been classified as safe for use in hazardous areas |
| fluid name | Text |
— | Optional | The name of the product in liquid or gas phase. |
| hydrostatic test pressure | Number |
bar gauge | Optional | A test pressure applicable when using water to establish the test pressure. |
| normal operating inlet pressure | Number |
bar absolute | Optional | An inlet pressure at which a functional or physical object is expected to operate normally. |
| normal operating inlet temperature | Number |
degree celsius | Optional | The temperature at which a functional or physical object is expected to operate normally at its inlet connection. |
| normal operating outlet pressure | Number |
bar absolute | Optional | The pressure at which a functional or physical object is expected to operate normally at its outlet connection. |
| normal operating outlet temperature | Number |
degree celsius | Optional | Is a temperature that occurs during operation or under which an object is supposed to operate. |
| number of passes | Number |
COUNT | Optional | Is a number of items where each item is a tube pass. |
| ATEX category | Text |
— | Optional | Specify in which category the physical object is divided in accordance with the directive 94/9/EC. |
| ATEX explosive atmosphere | Text |
— | Optional | Specify in which explosive atmosphere the physical object is divided in accordance with the directive 94/9/EC. |
| ATEX group | Text |
— | Optional | Specify in which group the physical object is divided in accordance with the directive 94/9/EC. |
| explosion protection concept | Text |
— | Optional | Specify the identification of electrical equipment's explosion protection and type of ignition protection in accordance with IEC/EN 60079-0. |
| explosion protection examination certificate number | Text |
— | Optional | The examination certificate number for the physical object issued by a notified body. |
| explosion protection material group | Text |
— | Optional | Specify for purposes of testing, approval, and area classification, various air mixtures (not oxygen-enriched) grouped in accordance with 500.6(A) and (B). |
| explosion protection notified body | Text |
— | Optional | The name of the nationally accredited approval body that has issued the examination certificate for the physical object. |
| floor material | Text |
— | Optional | The material from which the floor is constructed or an additional covering to strengthen or protect the surface of the floor structure. |
| head lining material | Text |
— | Optional | Is a material of construction of which a lining is made. |
| head material | Text |
— | Optional | Is a possessed aspect being a role of the substance of an artefact when used to construct the artefact from. Therefore the substance should be in a solid state at the conditions at which the artefact exists. |
| head wall thickness | Number |
millimetre | Optional | Is a thickness according to a design. |
| ingress protection | Text |
— | Optional | Specify the degree of ingress protection for the physical object in accordance with IEC/EN 50629 or NEMA, UL and CSA type rating. |
| legal registration number | Text |
— | Optional | Registration for legal reasons. |
| maximum tube metal temperature | Number |
degree celsius | Optional | Is a temperature that is the highest at which a significant load can be applied. |
| post weld heat treatment | Boolean |
— | Optional | Is a heat treatment after welding. Intended to ensure that the atomic structure of a weld and heat-affected zone is restored to an optimum corrosion-resistant structure. |
| shell material | Text |
— | Optional | Is a possessed aspect being a role of the substance of an artefact when used to construct the artefact from. Therefore the substance should be in a solid state at the conditions at which the artefact exists. |
| tube length | Number |
millimetre | Optional | A distance that is the length of a tube. |
| tube material specification | Text |
— | Optional | Is a specification which describes the applicable materials for one or more items. |
| tube outside diameter | Number |
millimetre | Optional | Is an outside diameter of an item that is the prime outside diameter in case the item has more than one outside diameter. |
| tube wall thickness | Number |
millimetre | Optional | Is a thickness according to a design. |