Definition & axiom
⚠ Conflicts with the ISO 15926-4 primary definition
Label (EN)
flame arrestor
Label (PT-BR)
Definition (EN)
Definition (PT-BR)
Semi-formal axiom (Aristotelian)
Axiom type
LLM classification basis: function-based → ≡
A flame arrestor is defined primarily by its safety function - preventing flames from entering a system. Any physical mechanism (metal mesh, ceramic elements, packed beds) that achieves flame arrest can instantiate this type. The identity is given by the FlameArrestFunction, not by a specific structural configuration.
Validation status
Why primitive (necessary only)
Reviewer notes
FOL theory & disjointness
First-order logic theory (generated)
Loading…
Disjoint with
▸
Expert review
Axiomatization steps
1
Identity-Giving Function
✓ done
⚠ not anchored
FlameArrestFunction → FlameArrestProcess
▼
COPI-Core operation
⚠ Process parent
PlannedProcess reaches no COPI-Core operation, and no gap (out of scope / coverage gap) is recorded.
LLM rationale:
The identity-giving function is flame arrest - preventing flame propagation from entering a system through an opening. This is a specific safety function that distinguishes flame arrestors from other safety devices or flow control equipment.
▸
Expert review
2
Genus Proximus
✓ done
MaterialArtifact
▼
Genus (genus proximum)
Most specific superclass — may be a domain class like "Valve" or an IOF-Core root.
BFO/IOF-Core Root
bfo:Object branch
bfo:ObjectAggregate branch
bfo:ImmaterialEntity branch
LLM rationale:
No appropriate domain superclass exists in the parent candidates. While 'ARRESTOR' appears in the hierarchy, it's too generic. 'ARTEFACT' is too broad. The concept requires a new intermediate genus 'SafetyDevice' for protective equipment, which would be a MaterialArtifact since flame arrestors are typically unitary devices installed in piping systems.
▸
Expert review
3
Differentia Specifica
✓ done
∃bearerOf.FlameArrestFunction ⊓ ∃participatesIn.FlameArrestProcess
▼
Conditions that distinguish
Flame Arrestor
from sibling classes under genus
MaterialArtifact.
Only what is not already entailed by the genus.
Differentia expression
Differentia (natural language)
LLM rationale:
The differentia specifies the flame arrest function and gas flow processing capability that distinguishes this from other safety devices under the same genus.
▸
Expert review
4
Necessary Parts
✓ done
no necessary parts
▼
Consider part-whole relations beyond subsumption:
hasComponentPartAtAllTimes (universal, structurally essential)
· hasComponentPartAtSomeTime (contingent, optional component)
LLM rationale:
These are the minimal essential parts - the functional arrest element and the structural housing to contain it and connect to the system.
▸
Expert review
5
Process Participation Signature ⟨I, O, T⟩
✓ done
PortionOfGas → PortionOfGas
▼
Inputs (I)
Outputs (O)
Transformation (T)
LLM rationale:
Flame arrestors process gas flows by removing flame fronts while allowing normal gas passage. The transformation is specifically flame extinguishment through physical mechanisms.
▸
Expert review
More
Alternative labels
none
▼
Synonyms / alternative labels (comma-separated) — skos:altLabel
Language auto-detected on export (PT if the label contains accents, EN otherwise).
Properties as BFO qualities
0 of 16 selected
▼
Select which CFIHOS/DEXPI properties inhere in every instance of Flame Arrestor as
bfo:Quality subclasses.
Each selected property →
:FlameArrestorQuality ⊑ bfo:Quality, inheres in :FlameArrestor
Custom axioms
none
▼
Axioms not produced by the pipeline. Each is appended verbatim as an
rdfs:subClassOf restriction on Flame Arrestor.
Write the restriction block in Turtle syntax (without the leading
rdfs:subClassOf).
Example: [ owl:onProperty :hasPart ; owl:someValuesFrom :Wellhead ]
Cross-standard divergences
none detected yet
▼
Click "Detect divergences" to analyse cross-standard disagreements for this cluster.